Versatile Capillary Column Temperature Control Using a Thermoelectric Array Based Platform
نویسندگان
چکیده
منابع مشابه
Versatile capillary column temperature control using a thermoelectric array based platform.
A new direct contact platform for capillary column precise temperature control based upon the use of individually controlled sequentially aligned Peltier thermoelectric units is presented. The platform provides rapid temperature control for capillary and microbore liquid chromatography columns and allows simultaneous temporal and spatial temperature programming. The operating temperature range ...
متن کاملDistillation Column Control Using the Whole Temperature Profile
Industrial distillation column control typically relies on one (or maybe two) carefully located tray temperature sensors. Here our aim is enhanced control by responding to movements in both the position and shape of the whole measured temperature profile. The control objective is to maintain end product specifications against feed composition disturbances using the measured temperatures and wit...
متن کاملNano-gels: A versatile nano -carrier platform for drug delivery systems: A mini review
Nowadays the application of nanotechnology in different biomedical fields such as drug delivery is increasing due to its unique advantages. With this in mind, it is widely believed that nanogels as the nanometer-sized networked polymeric particles have a considerable impact on drug delivery systems as biocompatible nanocarriers due to their unique characteristics such as high loading capacity, ...
متن کاملA versatile thermoelectric temperature controller with 10 mK reproducibility and 100 mK absolute accuracy.
We describe a general-purpose thermoelectric temperature controller with 1 mK stability, 10 mK reproducibility, and 100 mK absolute accuracy near room temperature. The controller design is relatively simple and could be readily modified for use in different experimental circumstances. We also describe a time-domain numerical model that allows one to characterize the stability and transient beha...