VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform

نویسندگان

چکیده

BackgroundVersaCross is a novel radiofrequency transseptal solution that may improve the efficiency and workflow of puncture (TSP). The aim this study was to compare VersaCross system with mechanical needle systems during mitral transcatheter edge-to-edge repair (M-TEER) PASCAL device.MethodsThis single-center retrospective consecutive patients who underwent M-TEER PASCAL. Transseptal undertaken either or wire. primary endpoints were success TSP successful delivery Edwards sheath on chosen Secondary included number wires used, tamponade rate, interval from femoral venous access first device deployment, procedural death, stroke.ResultsThirty-three (10 needle, 23 VersaCross) identified. All had TSP. In group, successfully delivered Superstiff Amplatz wire in all cases. arm, used for There no cases pericardial effusion/tamponade arm. Interval deployment shorter system. Significantly fewer VersaCross. deaths strokes group.ConclusionsVersaCross appears safe effective method 22Fr

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular Edge-to-Edge Mitral Valve Repair

Background—The edge-to-edge technique is an accepted method for the surgical repair of a regurgitant mitral valve. This study reports the initial use of an endovascular technology that enables a double-orifice edge-to-edge mitral valve repair without cardiopulmonary bypass in an animal model. Methods and Results—Adult pigs (n 14) were anesthetized, and left thoracotomy was performed for epicard...

متن کامل

The edge-to-edge technique for mitral valve repair

The edge-to-edge technique was introduced in the surgical armamentarium of mitral valve repair in 1991 and has progressively been used to restore mitral competence in the setting of degenerative, post-endocarditis and functional mitral regurgitation. Appropriate indications and awareness of the important technical aspects of the procedure are prerequisites for a good outcome. The free edges of ...

متن کامل

percutaneous mitral valve repair with the edge-to-edge technique: case series of first iranian experience

mitral regurgitation (mr) is a common valvular lesion in the general population with considerable impact on mortality and morbidity. the mitraclip system (abbot laboratories, abbot park, il, usa) is a novel percutaneous approach for treating mr which involves mechanical edge-to-edge coaptation of the mitral leaflets. we present our initial experience with the mitraclip system in 5 patients. in ...

متن کامل

Pulmonary Hemorrhage following Edge-to-Edge Mitral Valve Repair

Mitral valve repair with the MitraClip device has emerged as an effective treatment option for patients with severe mitral regurgitation and contraindications for surgical interventions. While the procedure is not known to cause pulmonary complications, we describe two cases of pulmonary hemorrhage following percutaneous mitral valve repair. The patients did well with supportive care and reinit...

متن کامل

Acute Mitral Regurgitation Secondary to Papillary Muscle Tear: Is Transcatheter Edge-to-Edge Mitral Valve Repair a New Paradigm?

Severe mitral regurgitation (MR) secondary to papillary muscle tear is an infrequent but overwhelmingly morbid and often fatal complication of acute myocardial infarction occurring in 1% to 3% of patients. In-hospital mortality without surgical correction can approach 80%; however, even with surgical correction, papillary muscle tear carries a mortality rate between 19% and 53%. While considera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Structural heart

سال: 2023

ISSN: ['2474-8706', '2474-8714']

DOI: https://doi.org/10.1016/j.shj.2023.100203