Verifying monitor unit calculations for tangential breast fields
An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. Differences between between sophisticated algorithms using 2.5D or 3D calculations and simpler Monitor unit check algorithms assuming a flat water phantom must be expected. For many anatomical sites such differences are small and of little or no consequence in the context of ...
متن کاملVerifying monitor unit calculations for tangential whole‐breast fields in three‐dimensional planning
An essential component of quality assurance in radiation therapy is verifying the accuracy of monitor unit calculations. For tangential breast fields, monitor unit differences between primary calculations and second checks are usually larger than considered acceptable at other anatomical sites. A simple model to reconcile the differences between sophisticated and simple algorithms is presented,...
متن کاملCorrections to traditional methods of verifying tangential‐breast 3D monitor‐unit calculations: Use of an equivalent triangle to estimate effective fields
This paper describes an innovative method for correctly estimating the effective field size of tangential-breast fields. The method uses an "equivalent triangle" to verify intact breast tangential field monitor-unit settings calculated by a 3D planning system to within 2%. The effects on verification calculations of loss of full scatter due to beam oblique incidence, proximity to field boundari...
متن کاملMonitor unit calculation for tangential breast treatments: Verification in an anthropomorphic phantom
This paper presents an anthropomorphic phantom study of dose delivered to a specific point during tangential breast irradiation to verify monitor unit calculations. Measurements were made using a 0.6 cc Farmer type cylindrical ionization chamber in the phantom and compared to calculations made on a three-dimensional radiotherapy treatment planning system using single digitized contour through t...
متن کاملEvaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...