Verifikasi Pergeseran Geometri Pesawat Linac Clinax CX Menggunakan Electronic Portal Imaging Device (EPID) Terdapat Kasus Kanker Nasofaring)

نویسندگان

چکیده

Telah dilakukan penelitian mengenai verifikasi pergesesaran geometri pada pesawat Linear Accelerator (Linac) tipe Clinax CX menggunakan Electronic Portal Imaging Device (EPID). Verifikasi 10 data rekam medis pasien kanker nasofaring di Instalasi Radioterapi Rumah Sakit Universitas Andalas. Proses diawali dengan perencanaan Treatment Planning System (TPS) Software Eclipse dilanjutkan penyinaran EPID. pergeseran berdasarkan titik koordinat X, Y, Z. Hasil menunjukkan terdapat yang melebihi standar IAEA Human Health Series No.31 Tahun 2016, yaitu sebanyak 2 1 dan Z karena mempunyai nilai pergesaran 0,3 cm. Faktor penyebab terjadinya signifikan adalah jauhnya jarak antara origin ke

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (epid)

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the p...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications

Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal Fisika Unand

سال: 2022

ISSN: ['2302-8491', '2686-2433']

DOI: https://doi.org/10.25077/jfu.11.4.482-486.2022