Performance assessment of a SOFC cogeneration system for residential buildings located in eastern Iran
It is expected that residential units may replace traditional heat and power production systems with cogeneration ones. Among the different cogeneration systems, fuel cell based systems are a suitable choice due to their high efficiency, high power density, low emission and low noise. In this paper, a cogeneration system based on solid oxide fuel cells is examined. The system, including the f...
متن کاملperformance assessment of a sofc cogeneration system for residential buildings located in east of iran
it is expected that residential units may replace traditional heat and power production systems with cogeneration ones. among the different cogeneration systems, fuel cell based systems are a suitable choice due to their high efficiency, high power density, low emission and low noise. in this paper, a cogeneration system based on solid oxide fuel cells is examined. the system, including the f...
متن کاملperformance assessment of a sofc cogeneration system for residential buildings located in eastern iran
it is expected that residential units may replace traditional heat and power production systems with cogeneration ones. among the different cogeneration systems, fuel cell based systems are a suitable choice due to their high efficiency, high power density, low emission and low noise. in this paper, a cogeneration system based on solid oxide fuel cells is examined. the system, including the f...
متن کاملAcrylic acid and electric power cogeneration in an SOFC reactor.
A highly efficient catalyst, MoV(0.3)Te(0.17)Nb(0.12)O, used for acrylic acid (AA) production from propane, was used as an anodic catalyst in an SOFC reactor, from which AA and electric power were cogenerated at 400-450 degrees C.
متن کاملDevelopment of a knowledge-based system for cogeneration plant design: Verification, validation and lessons learned
http://dx.doi.org/10.1016/j.knosys.2014.05.002 0950-7051/ 2014 Elsevier B.V. All rights reserved. ⇑ Corresponding author. Tel.: +55 48 3721 4002; fax: +55 48 3721 7615. E-mail addresses: [email protected] (J.C. da Silva), [email protected] (J.A. Matelli), [email protected] (E. Bazzo). 1 Tel.: +55 12 3123 2839; fax: +55 12 3123 2835. Jonny Carlos da Silva a,⇑, José Alexandre Matelli , Edson B...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ECS Proceedings Volumes
سال: 1997
ISSN: 0161-6374,2576-1579
DOI: 10.1149/199740.0094pv