Verification of ventilation accuracy of flow-inflating resuscitation bag with blind ventilation and manometer ventilation
نویسندگان
چکیده
منابع مشابه
Biphasic cuirass ventilation is better than bag-valve mask ventilation for resuscitation following organophosphate poisoning
OBJECTIVE Exposure to organophosphates (OP) may lead to a life threatening cholinergic crisis with death attributed to a rapidly progressive respiratory failure. In a toxicological mass casualty event involving organophosphate exposure, many of the victims may depend on immediate short-term ventilation to overcome the respiratory distress which may exhaust life supporting resources. In addition...
متن کاملCardiopulmonary resuscitation without ventilation.
Current resuscitation methods, although occasionally effective, rarely perform as well as initially anticipated. Some of the disappointment can be attributed to the difficulty of the task for many, including both professional and lay first responders. Significant attention has been paid recently to the need to simplify both the technique and the teaching of resuscitation. In considering simplif...
متن کاملComparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملComparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.
BACKGROUND Positive-pressure ventilation of patients with unprotected airways during cardiopulmonary resuscitation can cause gastric dilation. OBJECTIVE Determine if there is a significant difference in volume delivered to lungs and stomach while using an adult 1,000-mL disposable bag-valve-mask (BVM) device and the oxygen-powered, flow-limited Oxylator EMX resuscitator. METHODS We used a b...
متن کاملNeonatal resuscitation 3: manometer use in a model of face mask ventilation.
BACKGROUND Adequate ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation (PPV) is initiated with manual ventilation devices via face masks. These devices may be used with a manometer to measure airway pressures delivered. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal...