Verification data for electron beam dose algorithms
نویسندگان
چکیده
منابع مشابه
Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...
متن کاملElectron beam central axis depth dose measurements.
Central axis depth dose measurements were made by the Radiological Physics Center on over 70 electron-producing machines used in radiation therapy. These data were consistent for each machine model and nominal energy. However, the data show that depth dose relations can vary significantly among different machine models for electron beams having the same nominal energy. Analysis shows that both ...
متن کاملAlgorithms for Biological Dose Optimization in Ion Beam Radiotherapy
From 1997 until 2008 about 440 cancer patients were successfully treated in the ion therapy project at GSI. The patient treatment planning was performed with the software TRiP [1, 2]. A crucial part of the treatment planning is the particle number optimization with the goal to achieve a target dose distribution as close as possible to the prescribed biological dose distribution. The optimizatio...
متن کاملElectron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field
Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Va...
متن کاملEffect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy
Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 1992
ISSN: 0094-2405
DOI: 10.1118/1.596808