Ventricular Assist Device Driveline Infection and Development of Intracranial Hemorrhage
نویسندگان
چکیده
منابع مشابه
Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.
OBJECTIVES To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD). BACKGROUND Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice. METHODS A retrospective chart review was conducted on 68...
متن کاملLate driveline left ventricular assist device infection treated with frozen-and-thawed allogeneic platelet gel.
In this case report, we report the application of frozen-and-thawed allogeneic platelet gel (PLT-gel) to treat a late driveline exit site infection in a 56-year old patient supported by a Heartware-HVAD left ventricular assist device. The treatment duration was 4 weeks and at the follow-up the skin around the exit site was free from further infection. PLT-gel can be used to treat local infectio...
متن کاملMycotic Intracranial Aneurysm Secondary to Left Ventricular Assist Device Infection.
BACKGROUND Mycotic aneurysms are a complication of infective endocarditis. Infection of left ventricular assist devices (LVADs) may lead to bacteremia and fever causing complications similar to those seen in patients with prosthetic valve endocarditis. Intracranial mycotic aneurysms are rare, and their presence is signaled by the development of subarachnoid hemorrhage in the setting of bacterem...
متن کاملFDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.
can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...
متن کاملPharmacokinetic Assessment of Continuous Infusion Ceftolozane/Tazobactam for Drug-Resistant Pseudomonas aeruginosa Left Ventricular Assist Device Driveline Infection
Conclusion. Our findings suggest that the model can reasonably identify patients whose infections would be likely to be covered by cefazolin. Further, the majority of patients would have been covered by a narrower spectrum antibiotics than what they received. Research reported in this publication was supported by the National Institute of Allergy and Infectious Diseases of the NIH under Award N...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ASAIO Journal
سال: 2021
ISSN: 1058-2916
DOI: 10.1097/mat.0000000000001409