Ventolin Diskus and Inspyril Turbuhaler: An In Vitro Comparison
نویسندگان
چکیده
منابع مشابه
Ventolin Diskus and Inspyril Turbuhaler: an in vitro comparison.
Dose delivery (total emitted dose, or TED) from dry powder inhalers (DPIs), pulmonary deposition, and the biological effects depend on drug formulation and device and patient characteristics. The aim of this study was to measure, in vitro, the relationship between parameters of inhalation profiles recorded from patients, the TED and fine particle mass (FPM) of Diskus and Turbuhaler inhalers. In...
متن کاملVentolin Diskus and Inspyril Turbuhaler: An In Vitro Comparison
Dose delivery (total emitted dose, or TED) from dry powder inhalers (DPIs), pulmonary deposition, and the biological effects depend on drug formulation and device and patient characteristics. The aim of this study was to measure, in vitro, the relationship between parameters of inhalation profiles recorded from patients, the TED and fine particle mass (FPM) of Diskus and Turbuhaler inhalers. In...
متن کاملSkills in Handling Turbuhaler, Diskus, and Pressurized Metered-Dose Inhaler in Korean Asthmatic Patients
PURPOSE The objective of this study was to evaluate skills in handling inhalers and factors associated with these skills among patients with asthma who had undergone treatment at special asthma and allergy clinics in Korea. METHODS We enrolled 78 subjects who used Turbuhaler and 145 who used Diskus for asthma control at special clinics in 10 university hospitals and visually assessed their sk...
متن کاملUser error with Diskus and Turbuhaler by asthma patients and pharmacists in Jordan and Australia.
BACKGROUND Use of inhalers requires accurate completion of multiple steps to ensure effective medication delivery. OBJECTIVE To evaluate the most problematic steps in the use of Diskus and Turbuhaler for pharmacists and patients in Jordon and Australia. METHODS With standardized inhaler-technique checklists, we asked community pharmacists to demonstrate the use of Diskus and Turbuhaler. We...
متن کاملComparison of a new multidose powder inhaler (Diskus/Accuhaler) and the Turbuhaler regarding preference and ease of use.
Many patients with asthma or chronic obstructive pulmonary disease (COPD) use their inhaler ineffectively. Several studies revealed that inhaler-specific design features contributed significantly to the failure rate, which clearly demonstrates the need for developing more "foolproof" inhalers. This study compared ease of use and patient preference of the Diskus/Accuhaler (DA) with the Turbuhale...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Aerosol Medicine
سال: 2005
ISSN: 0894-2684,1557-9026
DOI: 10.1089/jam.2005.18.74