Vascular complications following intra-aortic balloon pump implantation: an updated review
نویسندگان
چکیده
منابع مشابه
Vascular complications following intra-aortic balloon pump implantation: an updated review
BACKGROUND The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with ...
متن کاملVascular complications of intra-aortic balloon pump usage in coronary bypass surgery: 18 years of experience.
OBJECTIVE To evaluate the vascular complication incidence related to intra-aortic balloon pump usage during coronary bypass surgery and possible risk factors. METHODS The retrospective study was conducted at Uludog University Hospital, Turkey, and comprised 147 cases in which intra-aortic balloon pump was used during coronary artery bypass surgery between January 1994 and December 2011. Data ...
متن کاملIntra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump
The increasing use of the intra aortic balloon pump is attributed to the relatively easy percutaneous insertion and the low threshold of use over the past few years, especially in elderly patients with multi-vessel diseases and an affected ejection fraction.Unfortunately, the clinical assessment of the complications associated to the use of this supporting device, underestimates the frequency o...
متن کاملIntra-Aortic Balloon Pump Rupture and Entrapment
Intra-aortic balloon pump is used frequently to support a failing myocardium in cardiac patients. Due to the invasive nature of this device, usage is accompanied by consistent risk of complications. Balloon rupture, although it occurs rarely, may lead to entrapment if diagnosis delays. A 78-year male who underwent cardiac surgery experienced balloon rupture and entrapment in the right femoral a...
متن کاملIntra-aortic balloon pump for oesophageal dilatation.
We read with interest the article by Loubani et al. [1] regarding the use of intra-aortic balloon pumps (IABP) for dilating oesophageal strictures. There are fundamental reasons why IABP is not the instrument of choice for oesophageal dilatation, even in difficult cases. IABP was never designed as a dilator. Its function is to produce diastolic augmentation of coronary and systemic blood flow b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Perfusion
سال: 2017
ISSN: 0267-6591,1477-111X
DOI: 10.1177/0267659117727825