Variational Mode Decomposition-based Synchronous Multi-Frequency Electrical Impedance Tomography

نویسندگان

چکیده

Electrical Impedance Tomography (EIT) can perform non-invasive, low-cost, safe, fast, and simple system structure functional imaging to map the distribution changes of root zone. Multi frequency EIT solves problem that single-frequency only carry more impedance information than a given single excitation frequency. It still remains challenges simultaneously obtain multi-frequency electrical tomography. To address problem, mixed signal superimposed by multiple frequencies is injected object. Essentially, separating measured voltage signals, which be used at different same time quickly. Since measurement signal, effect decomposing directly affects accuracy imaging. In order accurate data, this article variational mode decomposition (VMD) method decompose signal. Accurate amplitude phase could obtained in excitation, these data reconstruct The results showed proposed achieve expected effect. was concluded using modal process signals better, it applied practice.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variational constraints for electrical-impedance tomography.

The task of electrical impedance tomography is to invert electrical boundary measurements for the conductivity distribution of a body. This inverse problem can be formulated so the primary data are the measured powers dissipated across injection electrodes. Then, since these powers are minima of the pertinent variational principles (Dirichlet's or Thomson's principle), feasibility constraints c...

متن کامل

A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System

A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interfac...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Multi-electrode systems for electrical impedance tomography.

A wide range of electrode system designs is reviewed for their possible use in UT

متن کامل

System Description and First Application of an FPGA-Based Simultaneous Multi-Frequency Electrical Impedance Tomography

A new prototype of a multi-frequency electrical impedance tomography system is presented. The system uses a field-programmable gate array as a main controller and is configured to measure at different frequencies simultaneously through a composite waveform. Both real and imaginary components of the data are computed for each frequency and sent to the personal computer over an ethernet connectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Information Technology and Control

سال: 2022

ISSN: ['1392-124X', '2335-884X']

DOI: https://doi.org/10.5755/j01.itc.51.3.30014