Valve in Valve Trans-Catheter Aortic Valve Replacement Followed by LVAD Deactivation in the Setting of Recovered Systolic Function
نویسندگان
چکیده
منابع مشابه
Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
OBJECTIVE The treatment strategy for aortic stenosis (AS) has been changing due to newly developed valvular prostheses and trans-catheter aortic valve implantation (TAVI). To determine the role of new modalities for AS with a small aortic root, papers using the concept of prosthesis-patient mismatch (PPM) were reviewed. METHODS First, to determine the cut-off value of the indexed effective or...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملTransient systolic hypertension after aortic valve replacement.
Transient systolic hypertension, particularly during the 6 hours after operation, was found to be a significant complication in a series of33 consecutive cases ofaortic valve replacement. This rise in systolic blood pressure occurred in spite of treatment and was more common in cases ofpredominant aortic stenosis. It was not found after mitral valve replacement and there was no difference be; t...
متن کاملTranscatheter aortic valve replacement for bioprosthetic aortic valve failure: the valve-in-valve procedure.
2542 B ioprosthetic valves are increasingly used in patients with aortic stenosis. Compared with mechanical valves, bio-prosthetic valves are associated with a lower risk of thrombo-embolic events and do not require long-term anticoagulation. 1,2 However, bioprosthetic valves have limited durability; the best current valves can be expected to degenerate within 10 to 20 years, resulting in steno...
متن کاملValve-in-Valve Replacement Using a Sutureless Aortic Valve
BACKGROUND We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. CASE REPORT The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Current Cardiology Reviews
سال: 2020
ISSN: 1573-403X
DOI: 10.2174/1573403x15666190509082833