Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists

PURPOSE The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT1 and VT2) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance. METHODS Fourteen aerobically-trained male cyclists ([Formula: see text] 62.1±4.6 ml·kg-1·min-1) per...

متن کامل

The midpoint between ventilatory thresholds approaches maximal lactate steady state intensity in amateur cyclists

The aim was to determine whether the midpoint between ventilatory thresholds (MPVT) corresponds to maximal lactate steady state (MLSS). Twelve amateur cyclists (21.0 ± 2.6 years old; 72.2 ± 9.0 kg; 179.8 ± 7.5 cm) performed an incremental test (25 W·min-1) until exhaustion and several constant load tests of 30 minutes to determine MLSS, on different occasions. Using MLSS determination as the re...

متن کامل

Comparison between anaerobic threshold determined by ventilatory variables and blood lactate response in cyclists

Many investigations have shown that the coincidence between the ventilatory thresholds and those thresholds using the lactate response does not happen all of the time, suggesting that there is no relationship between the cause-effect between these phenomena. Thus, the present study had as main purpose to compare and correlate the Oxygen consumption (VO2), the power (W), and the heart rate (HR) ...

متن کامل

Relationship between the lactate and ventilatory thresholds during prolonged exercise.

The anaerobic threshold is commonly measured by either blood lactate (lactate threshold) or ventilatory gases (ventilatory threshold); however, the relationship between these 2 methods is not conclusive. The lactate threshold has been characterised at either a fixed or variable blood lactate concentration (BLa). Recent studies have indicated a specific blood lactate concentration for each indiv...

متن کامل

Determination of Blood Lactate Concentration: Reliability and Validity of a Lactate Oxidase-based Method

Int J Exerc Sci 2(2): 83-93, 2009. The measurement of blood lactate has long been used as marker of exercise intensity and training status. We compared a commercially available lactate oxidase spectrophotometric method (LO) to determine blood lactate levels to two previously validated methods, the lactate dehydrogenase spectrophotometric method (LDH), and the YSI 1500L Sport lactate analyzer (Y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLOS ONE

سال: 2016

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0163389