The aim of this study was to apply the technique of (109)Cd-based K-shell X-ray fluorescence (XRF) bone lead measurements to swine femurs and to validate the concentrations obtained therefrom against an independent chemical measurement of bone lead: atomic absorption spectrometry (AAS). The femurs ranged in lead concentration from 1.0 to 24.5 microg of lead per gram of ashed bone, as measured b...

متن کامل

Bone lead measured by X-ray fluorescence: epidemiologic methods.

In vivo X-ray fluorescence (XRF) measurement of bone lead concentration (XRF) has emerged as an important technique for future epidemiological studies of long-term toxicity. Several issues germane to epidemiologic methodology need to be addressed, however. First, sources of variability in measurements of bone lead need to be quantified, including imprecision related to the physical measurement ...

متن کامل

GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER

An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

An interlaboratory comparison of bone lead measurements via K-shell X-ray fluorescence spectrometry: validation against inductively coupled plasma mass spectrometry.

(109)Cd-based K-shell X-ray fluorescence spectrometry (hereafter, for brevity, XRF) is used, often in epidemiological studies, to perform non-invasive, in vivo measurements of lead in bone. We conducted the first interlaboratory study of XRF via the circulation of nine goat tibiæ in which the mean lead value ranged from 4.0 µg g(-1) to 55.3 µg g(-1) bone mineral. The test tibiæ were subsequentl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Environmental Health Perspectives

سال: 2001

ISSN: 0091-6765,1552-9924

DOI: 10.1289/ehp.011091115