Validation of the Stabil-O-Graph blood pressure self-measurement device

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the mobil-O-Graph: 24 h-blood pressure measurement device.

OBJECTIVE Twenty-four-hour blood pressure measurement is of importance not only in the detection of hypertension but also in the detection of blood pressure changes in hypertensive and nonhypertensives over the day to identify, for example, nondipper hypertensives. This study describes the validation of the mobil-O-Graph according to the criteria of the British Hypertension Society (BHS). MET...

متن کامل

Validation of TM-2655 oscillometric device for blood pressure measurement.

OBJECTIVE To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, systolic blood pressure range was 84-208 mmHg and diastolic blood pressure ran...

متن کامل

Validation of the Omron HEM-907 device for blood pressure measurement.

BACKGROUND The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, 18 more subjects are selected making a total number of 33 subjects on which ...

متن کامل

Blood Pressure Measurement Device A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings

Abstract—The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to pre...

متن کامل

Validation of a fully automatic photoplethysmographic device for toe blood pressure measurement.

OBJECTIVES This study was designed to assess the accuracy and reliability of a new, portable, fully automated photoplethysmography (PPG) device for toe blood pressure (TBP) measurement. DESIGN Within-subject comparison with conventional laser Doppler (LD) measurement. MATERIALS AND METHODS Four TBP measurements were performed on both lower limbs, alternatively with LD and PPG in 200 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Human Hypertension

سال: 2007

ISSN: 0950-9240,1476-5527

DOI: 10.1038/sj.jhh.1002287