Validation of the Serpent 2 Monte Carlo code for reactor dosimetry applications
نویسندگان
چکیده
The verification and validation (V&V) of the Serpent 2 Monte Carlo code for 3-D reactor dosimetry applications is being carried out at VTT. Two code-to-code computational benchmark cases were calculated by MCNP 2. efficiency different variance reduction techniques was appraised. part currently includes two experimental benchmarks from SINBAD database: Pool Critical Assembly-Pressure Vessel Facility (PCA); H.B. Robinson-2 (HBR-2) Pressure Dosimetry Benchmark. All simulations replicate source specifications pin level thanks to development a flexible, geometry-independent, fixed definition applications. Good agreement found in all cases.
منابع مشابه
Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial
Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...
متن کاملApplication of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom
Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...
متن کاملSiemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code
Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...
متن کاملSerpent-2 Reactor Model Validation at the Vienna Triga Mark Ii Reactor
The Vienna TRIGA Mark II reactor was modelled by means of the Serpent-2 Monte Carlo burnup calculation code. The purpose of the modelling is the determination of core critical parameters and of nuclear fuel composition time evolution. This paper presents the Serpent-2 reactor model validation process carried out during the last year. Taking into account the irradiation history, the fuel composi...
متن کاملA review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications.
In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Epj Web of Conferences
سال: 2023
ISSN: ['2101-6275', '2100-014X']
DOI: https://doi.org/10.1051/epjconf/202327802002