Validation of passive samplers for monitoring of acetic and formic acid in museum environments

نویسندگان

چکیده

Abstract Acetic acid and formic are volatile pollutants leading to degradation of some heritage materials. They usually determined in museum environments with various types passive samplers. In this work, SKC UMEx 200 samplers, originally intended for sampling $$\hbox {NO}_{2}$$ NO 2 {SO}_{2}$$ SO , have been validated these organic acids. The rates, extraction efficiency, loss through reverse diffusion or during storage, capacity, detection limits were both For laboratory exposure, a known concentration acids was prepared flow-through reactor system at controlled temperature humidity, the samplers extracted, followed by analysis using ion chromatography. rates be 16.7 ml/min acetic 17.7 7-day exposure $${2.1}\,{\upmu }{\rm g/m}^3$$ 2.1 μ g / m 3 $${1.9}\,{\upmu }\hbox {g/m}^3$$ 1.9 g/m acid. method finally used air two case studies National Museum Slovenia, where concentrations range 2– $${54}\,{\upmu 54 determined.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring of Aquatic Environments Using Passive Samplers

A review is given on the development of passive samplers for aquatic environments. Passive samplers that are simple and easy to use and with minimal consumption of organic solvents to desorb the analytes from the trapping media are focused. New developments in quality assurance procedures are highlighted.

متن کامل

Acylation of hydrazides with acetic acid and formic acid.

In peptide synthesis, hydrazides are important intermediates for the azide coupling method. A hydrazide is converted to the corresponding azide in the presence of an acid and a nitrite. When acetic acid (or formic acid) is used as the acid, partial acetylation (or formylation) of the hydrazide occurs as a side reaction. Formylation of the hydrazide is much faster than acetylation. Removal of th...

متن کامل

construction and validation of the translation teacher competency test and the scale of students’ perceptions of translation teachers

the major purpose of this study was to develop the translation teacher competency test (ttct) and examine its construct and predictive validity. the present study was conducted in two phases: a qualitative phase as well as a quantitative phase. in the first phase of the study, the author attempted to find out the major areas of competency required for an academic translation teacher. the second...

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heritage Science

سال: 2021

ISSN: ['2050-7445']

DOI: https://doi.org/10.1186/s40494-021-00495-3