Validation of Minimal Luminal Area Measured by Intravascular Ultrasound for Assessment of Functionally Significant Coronary Stenosis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis.

OBJECTIVES This study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard. BACKGROUND The evaluation of significant LMCA stenosis remains challenging. METHODS We identified 112 patients with isolated ostial and shaft intermediate LMCA stenosi...

متن کامل

Validation of Intravascular Ultrasound-Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity

The authors assessed optimal intravascular ultrasound criteria for predicting functional significance of intermediate coronary lesions. Overall, 201 patients with 236 coronary lesions underwent intravascular ultrasound and invasive physiologic assessment preintervention. Fractional flow reserve (FFR) was measured at maximal hyperemia induced by intravenous adenosine infusion. FFR <0.80 at maxim...

متن کامل

Validation of Intravascular Ultrasound-Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity

The authors assessed optimal intravascular ultrasound criteria for predicting functional significance of intermediate coronary lesions. Overall, 201 patients with 236 coronary lesions underwent intravascular ultrasound and invasive physiologic assessment preintervention. Fractional flow reserve (FFR) was measured at maximal hyperemia induced by intravenous adenosine infusion. FFR <0.80 at maxim...

متن کامل

Validation of Intravascular Ultrasound-Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity

The authors assessed optimal intravascular ultrasound criteria for predicting functional significance of intermediate coronary lesions. Overall, 201 patients with 236 coronary lesions underwent intravascular ultrasound and invasive physiologic assessment preintervention. Fractional flow reserve (FFR) was measured at maximal hyperemia induced by intravenous adenosine infusion. FFR <0.80 at maxim...

متن کامل

Validation of intravascular ultrasound-derived parameters with fractional flow reserve for assessment of coronary stenosis severity.

BACKGROUND We assessed optimal intravascular ultrasound (IVUS) criteria for predicting functional significance of intermediate coronary lesions. METHODS AND RESULTS Overall, 201 patients with 236 coronary lesions underwent IVUS and invasive physiological assessment before intervention. Fractional flow reserve (FFR) was measured at maximal hyperemia induced by intravenous adenosine infusion. F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: JACC: Cardiovascular Interventions

سال: 2011

ISSN: 1936-8798

DOI: 10.1016/j.jcin.2011.02.013