Validation of Duplex Ultrasound Graft Surveillance in the Immediate Postoperative Period
نویسندگان
چکیده
منابع مشابه
Base deficit in the immediate postoperative period of open-heart surgery and patient outcome
Abstarct Background: Base deficit is a non-respiratory indicator of acid base status that evaluates the severity of shock at the cellular level. Base deficit results from cellular metabolism of pyruvate under anaerobic conditions. In this situation, base deficit is a sensitive marker of the magnitude of anaerobic metabolism and tissue oxygen deficit [1]. Several studies have shown a strong pos...
متن کاملCost-effectiveness of duplex ultrasound surveillance in spinal cord injury.
OBJECTIVE To determine cost-effectiveness of surveillance with duplex ultrasound for thromboembolic disease in individuals with acute traumatic spinal cord injury at admission to rehabilitation. DESIGN In this retrospective sequential case series study, individuals with traumatic spinal cord injury admitted to our rehabilitation facility between July 1, 1988, and December 31, 1998, were ident...
متن کاملPosition of patient and respiratory function in immediate postoperative period.
Respiratory function was studied in 19 patients placed in both the supine and sitting positions in the early postoperative period. Although the sitting position was expected to improve respiratory function, no such advantage was found; instead, a small but statistically significant deterioration in arterial oxygenation was found in most patients when sitting up. It is concluded that no respirat...
متن کاملevaluation of sadr eminence in safavid period
چکیده: یکی از دوره های مهم تاریخی ایران به لحاظ تأمین استقلال ملی مذهبی و حتی تأثیر آن بر فرهنگ و مذهب ایرانیان، دوره صفویه است. رسمیت دادن و رواج مذهب شیعه توسط شاه اسماعیل اول، یکی از مهمترین اقدامات این دولت محسوب می شود. بنابراین برای اجرای این سیاست، وی منصب صدارت را به عنوان منصبی مذهبی- حکو متی ایجاد کرد .این منصب از دوره ی تیموریان ایجاد شده بود ولی در اواخر این دوره اهمیت بیشتری یافت...
15 صفحه اولClinical validation of glucose pump test (GPT) compared with ultrasound dilution technology in arteriovenous graft surveillance.
BACKGROUND Blood flow (Qa) measurements are an important step in the surveillance protocol of haemodialysis vascular access (VA). The glucose pump test (GPT) is a new test for Qa measurement based on the dilution of a constant glucose infusion. The aim of this study is to verify the clinical accuracy of GPT in a graft surveillance protocol with sequential Qa measurements. METHODS In 30 chroni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AORTA
سال: 2019
ISSN: 2325-4637
DOI: 10.1055/s-0039-1688435