Validation of a novel high-sensitivity cardiac troponin assay
نویسندگان
چکیده
Abstract Background The accuracy for early identification of non-ST-elevation myocardial infarction (NSTEMI) in the emergency department must be determined all novel high-sensitivity cardiac troponin assays (hs-cTn). In this prospective, multi-centre study we developed rule-out algorithms a I (hs-cTnI) assay and compared it to established hs-cTnT hs-cTnI. Methods Two NSTEMI were from derivation cohort 977 patients assessed by Siemens Atellica IM hs-cTnI assay. Diagnostic performance was with (Roche) (Abbott) algorithms. derived tested two different validation cohorts (n=518 n=405, respectively). Results An admission sample algorithm (hs-cTnI (Siemens)) cutoff <5 ng/L had negative predictive value (NPV) 99.4–100.0%, sensitivity 98.3–100% specificity 46.7–56.5% cohorts. Sensitivity NPV similar, trended towards improvement over comparator (Figure 1). A 0–1 hour <10 Δ change <3 achieved 100% >70% both cohorts, similar (Table Conclusions Rule-out has comparable diagnostic hs-cTn Funding Acknowledgement Type funding sources: Public grant(s) – National budget only. Main source(s): grant: Western Norway Regional Health Authority.Private company funding: Healthineers AG
منابع مشابه
Analytical validation of a high-sensitivity cardiac troponin T assay.
BACKGROUND We report the development of a novel high-sensitivity cardiac troponin T (hs-cTnT) assay, a modification of the Roche fourth-generation cTnT assay, and validation of the analytical performance of this assay. METHODS Validation included testing of analytical sensitivity, specificity, interferences, and precision. We established the 99th percentile cutoff from healthy reference popul...
متن کاملBiological and analytical variability of a novel high-sensitivity cardiac troponin T assay.
BACKGROUND High-sensitivity cardiac troponin assays will augment the frequency of increased results, making important the determination of reference change values to distinguish acute from chronic increases. We assessed short- and long-term biological variability of cardiac troponin T (cTnT) in healthy subjects with a novel high-sensitivity (hs) assay. METHODS We collected blood from 20 healt...
متن کاملAssay imprecision and 99th-percentile reference value of a high-sensitivity cardiac troponin I assay.
We undertook a performance evaluation and determination of the 99th-percentile reference value for the Siemens cTnI-Ultra with a fully characterized population that had undergone noninvasive cardiac imaging. Permission for the study was obtained from the local research ethics committee. Participants 45 years of age were randomly selected from the practice lists of 7 representative local communi...
متن کاملHigh sensitivity cardiac troponin testing.
Bösner and colleagues have presented evidence for a simple rule for ruling out coronary artery disease in the primary care setting. It is noteworthy that no laboratory measurements have been included in their model, with reference to their introductory statement that “ ... electrocardiography and cardiac troponin test are of limited value in primary care... ” This point deserves some discussion...
متن کاملAnalytical validation and establishment of reference intervals for a ‘high-sensitivity’ cardiac troponin-T assay in horses
BACKGROUND Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. OBJECTIVE Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Heart Journal
سال: 2022
ISSN: ['2634-3916']
DOI: https://doi.org/10.1093/eurheartj/ehac544.1363