V02-08 SIMPLE, REAL-TIME INTRAOPERATIVE INTRARENAL PRESSURE MONITORING: METHODS AND APPLICATIONS
نویسندگان
چکیده
You have accessJournal of UrologyMisc. Benign Disease & Transplant Renovascular (V02)1 Sep 2021V02-08 SIMPLE, REAL-TIME INTRAOPERATIVE INTRARENAL PRESSURE MONITORING: METHODS AND APPLICATIONS Nabeel Shakir, and Lee Zhao ShakirNabeel Shakir More articles by this author , ZhaoLee View All Author Informationhttps://doi.org/10.1097/JU.0000000000001979.08AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION: OBJECTIVE: Historic methods measuring intrarenal pressure such as the Whitaker test required specialized equipment needing precise calibration. With advent sophisticated anesthesia monitors, transducers are available in most operating rooms. We present our technique for (IRP) intraoperatively with common equipment. Our hypothesis is that relief obstruction, IRP will decrease remain low. METHODS: Sterile arterial line tubing zeroed connected a nephrostomy tube Luer lock adapter three way stopcock allow periodic venting. A urethral catheter keeps bladder drained. The transduced recorded automatically log. Initially, rises due urine accumulating renal pelvis, an unrelieved obstruction. When beyond preset threshold, rise again until obstruction relieved. corrected, it should RESULTS: cases where we implemented technique. first case left ureteral transection managed robotic Boari flap. ureter incised, there rush pressurized urine. Concomitantly, decreases, remains low during reconstruction. second ureterolysis retroperitoneal fibrosis. Here demonstrate venting nephrostomy, which allows safely. Concurrent ureteroscopy demonstrates no synchronous intrinsic has decreased low, without further need drain nephrostomy.The final bilateral Here, right ureteropelvic junction seen bed dense been incised anteriorly drop noted simultaneously. This persists while being spatulated. Patency outcomes date excellent (6/7 patients) additional morbidity secondary measurement. CONCLUSIONS: now routine component upper urinary tract reconstructive practice, leveraging commonplace There minimal cost or time. Apart from allowing measurement, verifying potential future applications include stone disease. Further investigation into significance pressure, other measured parameters, may yield greater insights obstructive Source Funding: None © 2021 American Urological Association Education Research, Inc.FiguresReferencesRelatedDetails Volume 206Issue Supplement 3September 2021Page: e135-e136 Advertisement Copyright Permissions© Inc.MetricsAuthor Information Expand Loading ...
منابع مشابه
Real-time intraoperative monitoring of myocardial ischemia in noncardiac surgery.
FOR the past 15 yr, there has been intense interest in the anesthesia community in the detection of intraand postoperative myocardial ischemia as a means of optimizing patient care because of the accumulated evidence suggesting a strong association with perioperative cardiac morbidity and long-term outcome. ',*It is important to understand the limitations of the methods of detecting myocardial ...
متن کاملSensing and Monitoring Methods in Telerobotical Applications Fusing Real-time Video Transmission and Calibrated Virtual Reality
In this paper we present a new approach of Internet-based teleoperation applying calibrated virtual reality. The limited technical performance of the Internet in terms of bandwidth, delay, jitter and reliability make necessary to introduce new methods to provide clients with applicable control environment through the network. We are focusing on the negative effects of limited bandwidth and pres...
متن کاملImplantable Biosensors for Real-time Strain and Pressure Monitoring
Implantable biosensors were developed for real-time monitoring of pressure and strain in the human body. The sensor, which was wireless and passive, consisted of a soft magnetic material and a permanent magnet. When exposed to a low frequency AC magnetic field, the soft magnetic material generated secondary magnetic fields that also included the higher-order harmonic modes. Parameters of intere...
متن کاملSensor Technology and Applications to a Real - Time Monitoring System
Large-scale structures such as bridges, dams and buildings have caused countless fatalities in the past decades because engineers were not able to detect the early signs of failure. It is believed that with the implementation of a distributed sensor network, many of these unfortunate events could have been avoided. The ultimate goal in applying distributed sensors is for structures to combine m...
متن کاملSimple Event Correlator for real-time security log monitoring
When it comes to the security of the IT system, event logs play a crucial role. Today, many applications, operating systems, network devices and other system components are capable of writing security related event messages to log files. The BSD syslog protocol is an event logging standard supported by majority of OS and network equipment vendors, which allows one to set up a central log server...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Urology
سال: 2021
ISSN: ['0022-5347', '1527-3792']
DOI: https://doi.org/10.1097/ju.0000000000001979.08