UV-Spectrophotometric Determination of the Active Pharmaceutical Ingredients Meloxicam and Nimesulide in Cleaning Validation Samples with Sodium Carbonate

نویسندگان

چکیده

The spectrophotometric methods of determination the active pharmaceutical ingredients meloxicam and nimesulide were reviewed a simple UV-spectrophotometric method for these in industrial equipment cleaning validation samples was proposed. based on extraction residual quantities from manufacturing surface by concentrated sodium carbonate solution subsequent basic forms drugs at wavelength 362 nm 397 nimesulide. calibration graphs linear range 5 to 25 mg/L both meloxicam, molar attenuation coefficients 6100 m2/mol 9100 limit detection 0.8 1.9 quantification 2.5 5.8 meloxicam. selective with respect common excipients, showed good accuracy (the relative uncertainty did not exceed 7%) precision standard deviation 4%), require lengthy sample preparation or sophisticated laboratory suitable routine analysis samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The application of atomic absorption spectrometry for the determination of residual active pharmaceutical ingredients in cleaning validation samples.

The objective of this work was the development and validation of atomic absorption spectrometric (AAS) methods for the determination of residual active pharmaceutical ingredients (API) in rinse samples for cleaning validation. AAS as an indirect method for the determination of API in rinse samples can be applied when it is in the form of salt with metal ions or when the metal ion is a part of t...

متن کامل

UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome

The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg /mL range of hydroquinone an...

متن کامل

UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome

The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg /mL range of hydroquinone an...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: J

سال: 2023

ISSN: ['2571-8800']

DOI: https://doi.org/10.3390/j6020019