Using XRF and ICP-OES in Biosorption Studies
نویسندگان
چکیده
منابع مشابه
Using ICP-OES and SEM-EDX in biosorption studies
We have compared the analytical results obtained by inductively coupled plasma optical emission spectroscopy (ICP-OES) and by scanning electron microscopy with an energy dispersive X-ray analytical system (SEM-EDX) in order to explore the mechanism of metal ions biosorption by biomass using two independent methods. The marine macroalga Enteromorpha sp. was enriched with Cu(II), Mn(II), Zn(II), ...
متن کاملICP-OES, ICP-MS and AAS Techniques Compared
This article will briefly describe these three techniques, and point out the important criteria by which to judge their applicability to your own analytical problems. Table 1 below shows a checklist of common analytical requirements and may help in the assessment of the techniques. For many people with an ICP-OES background, ICP-MS is a plasma with a mass spectrometer as a detector. Mass spectr...
متن کاملDirect Determination of Lanthanides in Environmental Samples using Ultrasonic Nebulization and ICP OES
Baixas concentrações dos catorze elementos de ocorrência natural da série lantanídeos foram diretamente determinadas por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Avaliaram-se interferências espectrais e linhas espectrais mais adequadas foram selecionadas. Os desempenhos da nebulização pneumática e ultra-sônica foram comparados com respeito aos limites de det...
متن کاملElemental fingerprinting of Hypericum perforatum (St John's Wort) herb and preparations using ICP-OES and chemometrics.
St. John's wort (SJW) (Hypericum perforatum) is a herbal remedy commonly used to treat mild depression. The elemental profiles of 54 samples (i.e., dry herbs, tablets and capsules) were evaluated by monitoring 25 elements using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The major elemental constituents in the SJW samples were Ca (300-199,000μg/g), Mg (410-3,530μg/g), Al...
متن کاملHigh precision measurement of silicon in naphthas by ICP-OES using isooctane as diluent.
An analytical protocol for the accurate and precise determination of Si in naphthas is presented by using ICP-OES, optimizing from the sample preparation to the measurement conditions, in order to be able to analyze for the first time silicon contents below 100µgkg-1 in a relatively short time thus being used as a control method. In the petrochemical industry, silicon can be present as a contam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Molecules
سال: 2018
ISSN: 1420-3049
DOI: 10.3390/molecules23082076