Using Pd-Doped γ-Graphyne to Detect Dissolved Gases in Transformer Oil: A Density Functional Theory Investigation
نویسندگان
چکیده
منابع مشابه
Dissolved hydrogen gas analysis in transformer oil using Pd catalyst decorated on ZnO nanorod array
A resistivity-type hydrogen (H2) sensor based on palladium (Pd)-decorated zinc oxide (ZnO) nanorod (NR) array has been developed to detect the dissolved H2 gas in the transformer oil. The Pd catalyst decorated on the ZnO NRs not only enhanced the H2 sensing properties at room temperature, but also played an important role to protect the ZnO NRs in liquid environment, which resulted long-term st...
متن کاملA Density Functional Theory Investigation of d8 Transition Metal(II) (Ni, Pd, Pt) Chloride Complexes of Some Vic-dioximes Derivatives
Herein, a theoretical study on the stability of some vic-dioxime complexes of Ni(II), Pd(II) and Pt(II) in gas and aqueous phases is reported. The DFT/M06/SDD and DFT/M06/6-31G+(d,p) levels of theory were adopted for the metal ions and for every other element respectively. Structural analyses of investigated complexes have revealed square planar geometries stabilized by two O–H⋯Cl hydrogen bond...
متن کاملNew sensor for gases dissolved in transformer oil based on solid oxide fuel cell
Due to the poor anti-jamming performance, less gas species, low detection accuracy, short life, medium leaking or carbonmonoxide poisoning and other defects that current sensors for gases dissolved in transformer oil have, a SOFC-based multi-component gas sensor has been designed. The physical, chemical and electrochemical mechanisms of gases in the SOFC have been analyzed, and the mathematical...
متن کاملA Ni-Doped Carbon Nanotube Sensor for Detecting Oil-Dissolved Gases in Transformers
C2H2, C2H4, and C2H6 are important oil-dissolved gases in power transformers. Detection of the composition and content of oil-dissolved gases in transformers is very significant in the diagnosis and assessment of the state of transformer operations. The commonly used oil-gas analysis methods have many disadvantages, so this paper proposes a Ni-doped carbon nanotube (Ni-CNT) gas sensor to effect...
متن کاملA new fuzzy logic approach to identify power transformer criticality using dissolved gas-in-oil analysis
Dissolved gas analysis (DGA) of transformer oil is one of the most effective power transformer condition monitoring tools. There are many interpretation techniques for DGA results however all current techniques rely on personnel experience more than analytical formulation. As a result, the current techniques do not necessarily lead to the same conclusion for the same oil sample. A significant n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nanomaterials
سال: 2019
ISSN: 2079-4991
DOI: 10.3390/nano9101490