Using OLTC-Fitted Distribution Transformer to Increase Residential PV Hosting Capacity: Decentralized Voltage Management Approach

نویسندگان

چکیده

The increasing Photovoltaic (PV) penetration in residential Low Voltage (LV) networks is likely to result a voltage rise problem. One of the potential solutions deal with this problem adopt distribution transformer fitted an On-Load Tap Changer (OLTC). control OLTC response local measurements reduces need for expensive communication channels and remote measuring devices. However, requires developing advanced decision-making algorithm estimate existence issues define best set point OLTC. This paper presents decentralized data-driven approach operate using at (i.e., active power secondary side transformer). To do so, Monte Carlo simulations are utilized offline produce comprehensive dataset flows throughout customers’ voltages different PV penetrations. By application curve-fitting technique resulting dataset, models maximum minimum defined embedded into logic manage real time. UK LV feeder shows its effectiveness improving hosting capacity without monitoring elements.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Placement and Sizing of Battery Storage to Increase the Pv Hosting Capacity of Low Voltage Grids

The purpose of this thesis is to investigate the cost-optimal placement and sizing of battery storage as a PV integration measure in the distribution grid level. Additionally, potential synergies between PV generation, battery storage, smart PV curtailment and electric mobility are also explored within this thesis. Accordingly, a versatile optimization tool has been developed in order to identi...

متن کامل

An Analysis of Photo-Voltaic Hosting Capacity in Finnish Low Voltage Distribution Networks

The ascending trend of photo-voltaic (PV) utilization on a domestic scale in Finland, calls for a technical aspects review of low voltage (LV) networks. This work investigates the technical factors that limit the PV hosting capacity, in realistic case networks, designed relative to different geographical areas of Finland. A Monte Carlo method based analysis was performed, in order to quantify t...

متن کامل

PV Hosting Capacity Analysis and Enhancement Using High Resolution Stochastic Modeling

Reduction of CO2 emissions is a main target in the future smart grid. This goal is boosting the installation of renewable energy resources (RES), as well as a major consumer engagement that seeks for a more efficient utilization of these resources toward the figure of ‘prosumers’. Nevertheless, these resources present an intermittent nature, which requires the presence of an energy storage syst...

متن کامل

On the Der Hosting Capacity of Distribution Feeders

In the last two decades, there is significant increase in the grid connected distributed energy resources (DER) worldwide. At the distribution level, a high DER penetration provides a number of challenges for the Distribution system operators (DSOs) concerning the operation and planning of their electricity networks. Despite these operational problems, DSOs are often faced with high political p...

متن کامل

Transient Voltage Distribution in Transformer Winding (experimental Investigation)

Abstract In this work, the non-liner voltage distribution in transformer winding is investigated that occurs due switching and lightning. Transformer winding is modeled in the alternative transients program (ATP) version of Electromagnetic transients program (EMTPRV). EMTP software is used to simulate the very fast transient overvoltage. An experimental setup that consist of , Recurrent surge g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2022

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en15134836