Using a patterned microtexture to reduce polyethylene wear in metal-on-polyethylene prosthetic bearing couples

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermedi...

متن کامل

A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints.

More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily a...

متن کامل

Wear of moderately cross-linked polyethylene fixed bearing knee replacements

Cross-linked polyethylene has been explored as an alternative to conventional polyethylene in total joint replacement in order to reduce wear volume and decrease failure through polyethylene wear debris induced osteolysis [1]. Due to the demands of a total knee replacement, moderately cross-linked polyethylene is recommended to retain mechanical properties [2]. This study aims to investigate th...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

Isolated polyethylene exchange versus acetabular revision for polyethylene wear.

UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Wear

سال: 2017

ISSN: 0043-1648

DOI: 10.1016/j.wear.2017.09.014