Usefulness of the Icare ic200 Rebound Tonometer in Korean
نویسندگان
چکیده
목ì 리ë°ì´ëììê³ Icare ic200ì¼ë¡ 측ì í ììì 골ëë§ìíììê³ë¡ ììê³¼ ë¹êµíì¬ ìììì ic200ì ì ì©ì±ì íì¸íê³ ì íìë¤. ëìê³¼ ë°©ë² ì ì²´ íêµì¸ 294ëª , 294ìì´ ì°êµ¬ì í¬í¨ëìë¤. 모ë íììì ë¤ íìë¤. ë ììê³ì ìì ì¼ì¹ë를 íê°íìì¼ë©°, 골ëë§ìíììê³ì 22 mmHg ì´ìì ëí ì§ë¨ë¥ì ë¶ìíìë¤. ìì²´ê³ì¸¡ì í¬í¨í ììì¸ìë¤ì´ ììê³ë¡ ë ììì ì°¨ì´ì ìí¥ì 미ì¹ëì§ ê²°ê³¼ ììì ê°í ìì ìê´ê´ê³ë¥¼ ë³´ìë¤(r=0.875, p<0.001). ììì´ ììë³´ë¤ íê· 3.07 ± 2.67 ë®ìê³ Bland-Altman plotsìì 95.24%ì íìê° 95% ì¼ì¹íê³(-2.16 to 8.30 mmHg) ìì ë¶í¬íë¤. ì´ìì ê³ ììì ì§ë¨ë¥ì 0.959 (area under the receiver operating characterisitic)ìë¤. ë¤ë³ëíê·ë¶ì ëì´ê° ë§ì ê²(β=0.034, p=0.020)ê³¼ ê°ë§ê³¡ë¥ ì´ ëì ê²(β=0.213, p=0.030)ì´ ì°¨ì´ê° í° ê²ê³¼ ì°ê´ë ê²ì¼ë¡ ëíë¬ë¤. ê²°ë¡ ic200ì 골ëë§ìíììê³ì ì¢ì ì¼ì¹ë ë° ë³´ìì¼ë, 3 ë®ê² ëìë¤. ë°ë¼ì 골ëë§ìíììê³ë¥¼ ëì²´í´ì ì¬ì©í기보ë¤ë ì ë³ê²ì¬ì ì©íê² ì¬ì©ë ì ìì ë³´ì¸ë¤. Keywords: Glaucoma, Goldmann applanation tonometer, ic200, Rebound tonometer
منابع مشابه
Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the res...
متن کاملComprasion of ICare Rebound Tonometer and Goldmann Applanation Tonometer in High Myopia
PURPOSE To compare intraocular pressure (IOP) measurements with the Goldmann applanation tonometer (GAT) and the ICare rebound tonometer (RBT) in high myopic eyes. PATIENTS AND METHODS This randomized prospective study included 40 eyes of 40 patients with high myopia. All patients' central corneal thickness (CCT), anterior chamber depth (ACD), axial length (AXL), keratometry, and refractive m...
متن کاملDiagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.
BACKGROUND Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate...
متن کاملAccuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication.
BACKGROUND The purpose of this study was to assess the accuracy of the ICare tonometer, using the Perkins applanation tonometer (AT) as the reference, in a sample population being treated with travaprost 0.004% for glaucoma. MATERIAL AND METHODS Twenty-eight consecutive patients with open-angle glaucoma or ocular hypertension who had been receiving travaprost 0.004% to control elevated intrao...
متن کاملEvaluation of the ICare rebound tonometer as a home intraocular pressure monitoring device.
PURPOSE (a) To investigate whether the ICare rebound tonometer can provide accurate measurements of intraocular pressure (IOP) in the hands of an inexperienced user compared with ICare measurements and Goldmann tonometry by a trained technician and (b) to assess the intrauser reproducibility of IOP measurements and the learning curve among patients using the ICare rebound tonometer. METHODS A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of The Korean Ophthalmological Society
سال: 2021
ISSN: ['0378-6471', '2092-9374']
DOI: https://doi.org/10.3341/jkos.2021.62.5.665