Use of lysis-centrifugation (isolator) and radiometric (BACTEC) blood culture systems for the detection of mycobacteremia

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.

In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Sep...

متن کامل

Clinical comparison of lysis-centrifugation and radiometric resin systems for blood culture.

The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) and the BACTEC 16B-17D radiometric resin system (Johnston Laboratories, Inc., Towson, Md.) both remove antimicrobial agents from the blood for culture. We compared these two systems for recovery of aerobic bacteria, facultatively anaerobic bacteria, and yeasts. A total of 5,000 blo...

متن کامل

Comparison of BACTEC 13A medium and Du Pont isolator for detection of mycobacteremia.

BACTEC 13A medium (Johnston Laboratories, Towson, Md.) was compared with Isolator (Du Pont Co., Wilmington, Del.) concentrate for sensitivity, speed, and technical ease of isolation of mycobacteria from paired patient blood samples. Of 72 positive cultures, 63 were positive by both systems. Five positive cultures were detected by BACTEC 13A medium alone, and four were detected by Isolator alone...

متن کامل

Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...

متن کامل

Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the bloo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 1985

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.22.4.543-546.1985