Use of Airtraq, C-Mac, and Glidescope laryngoscope is better than Macintosh in novice medical students′ hands: A manikin study
نویسندگان
چکیده
منابع مشابه
Comparing McGRATH® MAC, C-MAC®, and Macintosh Laryngoscopes Operated by Medical Students: A Randomized, Crossover, Manikin Study
We hypothesized that the McGRATH MAC would decrease the time of intubation compared to C-MAC for novices. Thirty-nine medical students who had used the Macintosh blade to intubate a manikin fewer than 3 times were recruited. The participants performed sequential intubations on the manikin in two simulated settings that included a normal airway and a difficult airway (tongue edema). The intubati...
متن کاملTeaching tracheal intubation: Airtraq is superior to Macintosh laryngoscope
BACKGROUND Tracheal intubation with Macintosh laryngoscope is taught to medical students as it is a lifesaving procedure. However, it is a difficult technique to learn and the consequences of intubation failure are potentially serious. The Airtraq optical laryngoscope is a relatively novel intubation device, which allows visualization of the glottic plane without alignment of the oral, pharynge...
متن کاملComparison of airway management associated hands-off time between Macintosh and Airtraq®: A randomized manikin trial.
متن کامل
Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study.
The Airtraq Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and tracheal axes. We compared the Airtraq with the Macintosh laryngoscope in simulated easy and difficult laryngoscopy. Twenty-five anaesthetists were allowed up to three attempts to intubate the trachea in each of three laryngoscopy scenarios using a La...
متن کاملAn evaluation of a modified Macintosh laryngoscope in a manikin.
PURPOSE In this manikin study a modified Macintosh blade was prospectively compared with its original focussing on the forces exerted on the maxillary incisor teeth and intubation success. The modified blade, a standard Macintosh blade with a reduced proximal flange, was intended to reduce the forces exerted on the maxillary incisors. METHODS A manikin equipped with two sensors, to measure fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Saudi Journal of Anaesthesia
سال: 2011
ISSN: 1658-354X
DOI: 10.4103/1658-354x.87266