Unintentional Staining of the Anterior Vitreous with Trypan Blue During Cataract Surgery
نویسندگان
چکیده
منابع مشابه
[Unintentional staining of lens posterior capsule with trypan blue during extracapsular cataract extraction: case report].
Report of a complication related to the use of 0.1% trypan blue during capsular staining of the anterior crystalline lens capsule in an extracapsular cataract extraction with intraocular lens implantation. The capsular dye was injected using an air-bubble technique, inadvertently, it was done using high pressure dispersing the dye through the zonules leading to a complete lost of red reflex, th...
متن کاملInadvertent Trypan Blue Staining of Posterior Capsule during Cataract Surgery Associated with "Argentinian Flag" Event.
Trypan blue is common in visualizing the anterior capsule during cataract surgery. Inadvertent staining of the posterior capsule during phacoemulsification is a rare complication and there are few reports in the literature. The proposed mechanism of posterior capsule staining in previous reports includes a compromised zonular apparatus or iris retractors facilitating the posterior flow of trypa...
متن کاملCrystalline lens capsule staining with trypan blue.
A 1-step method for staining the anterior lens capsule with trypan blue is described. The dye is instilled via a paracentesis port at the start of cataract extraction. As aqueous humor is allowed to exit the anterior chamber (AC), which consequently shallows, the resulting pupil block confines the dye to the AC. An ophthalmic viscosurgical device (OVD) is used to flush dye-stained aqueous from ...
متن کاملTrypan blue-assisted posterior capsulorhexis in pediatric cataract surgery
PURPOSE To evaluate the safety and efficacy of staining the posterior capsule with trypan blue during capsulorhexis in pediatric cataract surgery. PATIENTS AND METHODS This was a prospective randomized comparative study carried out at Alpha Vision Center, Zagazig, Egypt. This study included 2 groups of children with pediatric cataract randomly allocated to undergo irrigation and aspiration. I...
متن کاملUnder-air staining of the anterior capsule using Trypan blue with a 30 G needle
The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Turkish Journal of Ophthalmology
سال: 2020
ISSN: 1300-0659,2147-2661
DOI: 10.4274/tjo.galenos.2020.94580