Unintentional Passive Islanding Detection and Prevention Method with Reduced Non-Detection Zones
نویسندگان
چکیده
Islanding detection and prevention are involved in tandem with the rise of large- small-scale distribution grids. To detect islanded buses, either voltage or frequency variation has been considered literature. A modified passive islanding strategy that coordinates V-F (voltage–frequency) index was developed to reduce non-detection zones (NDZs), an operation is proposed this article. Voltage were measured at each bus check violation limits by implementing strategy. The power mismatch alleviated identified islands installing a battery diesel generator, which prevented events. studied on three distinct IEEE radial systems, namely, 33-, 69-, 118-bus systems. results obtained above-mentioned systems promising when implemented. compared those methods recent As result, time number buses reduced.
منابع مشابه
A Novel Passive Method for Islanding Detection in Microgrids
Integration of distributed generations (DGs) in power grids is expected to play an essential role in the infrastructure and market of electrical power systems. Microgrids are small energy systems, capable of balancing captive supply and requesting resources to retain stable service within a specific boundary. Microgrids can operate in grid-connected or islanding modes. Effective islanding detec...
متن کاملislanding detection methods for microgrids
امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...
15 صفحه اولAn Integrated Passive Islanding Detection Method for Distributed Generators
This study proposes a new islanding detection method for use of grid-interconnected distributed generators (DG). The method is based on two indices: the rate of change of frequency (ROCOF) and the rate of change of voltage (ROCOV). When a DG is grid-interconnected, the ROCOF and ROCOV are lower than the threshold value. In contrast, as an islanding occurs, the ROCOF or ROCOV become much higher ...
متن کاملIslanding Detection Method of Distributed Generation Based on Wavenet
Due to the increasing need to distributed energy resources in power systems, their problems should be studied. One of the main problem of distributed energy resources is unplanned islanding. The unplanned islanding has some dangers to the power systems and the repairman which are works with the incorrect devices. In this paper, a passive local method is proposed. The proposed method is based on...
متن کاملInvestigation of Active and Passive Islanding Detection Techniques
This paper presents an investigation of different islanding detection techniques which focus on operating parameters. These parameters are to decide whether the system will be islanded or not. The process is based on measuring the voltage, frequency and phase angle at the point of common coupling. The rate of change must be integrated to distinguish the changes in the system, the rate of change...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2022
ISSN: ['1996-1073']