Uniaxial tension test on Rubber at constant true strain rate
نویسندگان
چکیده
منابع مشابه
Uniaxial True Stress-Strain after Necking - Tyco Electronics
A weighted-average method for determining uniaxial, true tensile stress vs. strain relation after necking is presented for strip shaped samples. The method requires identification of a lower and an upper bound for the true stress-strain function after necking and expresses the true stress-strain relation as the weighted average of these two bounds. The weight factor is determined iteratively by...
متن کاملExtended ensemble molecular dynamics method for constant strain rate uniaxial deformation of polymer systems
We describe a novel molecular dynamics ~MD! method to simulate the uniaxial deformation of an amorphous polymer. This method is based on a rigorously defined statistical mechanics ensemble appropriate for describing an isothermal, displacement controlled, uniaxial stress mechanical test. The total number of particles is fixed and the normal stresses in the direction normal to the applied strain...
متن کاملThe uniaxial stress versus strain response of pig skin and silicone rubber at low and high strain rates
The uniaxial compressive responses of silicone rubber (B452 and Sil8800) and pig skin have been measured over a wide range of strain rates (0.004–4000 s ). The uniaxial tensile response of the silicone rubbers was also measured at low strain rates. The high strain rate compression tests were performed using a split-Hopkinson pressure bar made from AZM magnesium alloy. High gain semi-conductor s...
متن کاملUniaxial Tension Test of Slender Reinforced Early Age Concrete Members
The present study aims to obtain the tensile properties of early age concrete based on a uniaxial tension test employing RC slender members. First, the paper shows that concrete strain is equal to the strain of rebar at the mid-span of the RC member. The tensile Young's modulus and the strain capacity of early age concrete are estimated using strain measurements. The experiment indicated that t...
متن کاملHigh strain-rate behavior of ice under uniaxial compression
In the present study, a modified split Hopkinson pressure bar (SHPB) is employed to investigate the dynamic response of ice under uniaxial compression in the range of strain rates from 60 to 1400 s 1 and at initial test temperatures of 10 and 30 C. The compressive strength of ice shows positive strain-rate sensitivity over the range of strain rates employed; a slight influence of ice microstruc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EPJ Web of Conferences
سال: 2012
ISSN: 2100-014X
DOI: 10.1051/epjconf/20122601011