Undulating Wear Mechanism of Overhead Rigid Conductor Line
نویسندگان
چکیده
منابع مشابه
EMTP Modeling of a Triggered-Lightning Strike to the Phase Conductor of an Overhead Distribution Line
A triggered-lightning experiment and EMTP modeling of that experiment are used to study the responses of a twoconductor overhead power line to a direct lightning strike. The experiment was conducted at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, FL. The lightning was artificially initiated (triggered) from a natural thundercloud using the rocket-and-wir...
متن کاملModeling of Rogowski Coil for On-line Pd Monitoring in Covered- Conductor Overhead Distribution Networks
In this paper, EMTP/ATP simulation environment is used to model the Rogowski coil for partial discharge (PD) monitoring due to leaning trees on the covered-conductor (CC) overhead distribution lines. The simulations are performed to obtain the Rogowski coil response at different lengths of the CC line and the results are compared with those obtained from the laboratory measurements. The results...
متن کاملDifferential GPS Measurement of Overhead Conductor Sag: Software Implementation
(PSERC). PSERC is a multi-university Center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. of Entergy-New Orleans. In early stages of the project, Mr. Lance Priez of Entergy supplied needed information. The many useful suggestions of all the industrial advisors are acknowledged. Dale Bradshaw of the Tennesse...
متن کاملPartial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines
Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Muzamir Isa Name of the doctoral dissertation Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines Publisher School of Electrical Engineering Unit Department of Electrical Engineering Series Aalto University publication series DOCTORAL DISSERTATIONS 9/2013 Field of research Power Systems and H...
متن کاملDelamination Wear Mechanism in Gray Cast Irons
An investigation of the friction and sliding wear of gray cast iron against chromium plated cast irons was carried out on a newly constructed reciprocating friction and wear tester. The tests were the first to be done on the test rig under dry conditions and at the speed of 170 cm/min, and variable loads of 20-260 N for a duration of 15 min. to 3 hours. The gray cast iron surfaces worn by a pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 2006
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.126.109