Understanding of XLPE Cable System Commissioning using Partial Discharge Measurements during AC HV Tests

نویسندگان

چکیده

This paper is based on the work done by Altanova Group, India, and describes process procedures used in a Partial Discharge (PD) investigation cable circuit during AC withstand test. The focuses two most common approaches employed, namely, soak tests resonant tests. In latter case, to performing measurements relative benefits of each. De-noising acquired data using T-F map analysis also described, real-world examples are given case studies. These detail EHV tests, one performed where all accessories were monitored simultaneously another each accessory was tested turn before relocating PD monitoring equipment next location. both cases, application maps shows how different sources, such as external corona, can be identified hence segregated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Discharge (PD) HV and EHV Power Cable Systems

This chapter represents the state of the art at the time of release. Readers are encouraged to consult the link below for the version of this chapter with the most recent release date: Neither NEETRAC, GTRC, any member of NEETRAC or any cosponsor nor any person acting on behalf of any of them: a) Makes any warranty or representation whatsoever, express or implied, i. With respect to the use of ...

متن کامل

On-line Partial Discharge Monitor System of XLPE Power Cable Based on Virtual Instrument

High voltage XLPE power cable is a very important part of power system. The degree of electric-tree aging in the cable can be estimated effectually by measuring partial discharge. An on-line partial discharge monitor system of XLPE power cable was developed based on the virtual instrument designing conception. This system has the advantage of wide analog bandwidth, excellent anti-interference a...

متن کامل

Research on Partial Discharge Localization in XLPE Cable Accessories Using Multi-Sensor Joint Detection Technology

A multi-sensor joint detection technology was proposed based on the theory of the high frequency current transformer (HFCT) method, Ultra-high frequency (UHF) method and acoustic emission (AE) method. An experimental partial discharge (PD) testing was applied on XLPE cable with artificial defect signals. The experimental results show that the multi-sensor joint detection technology will help to...

متن کامل

Medium Voltage Cable System Partial Discharge

This chapter represents the state of the art at the time of release. Readers are encouraged to consult the link below for the version of this chapter with the most recent release date: Neither NEETRAC, GTRC, any member of NEETRAC or any cosponsor nor any person acting on behalf of any of them: a) Makes any warranty or representation whatsoever, express or implied, i. With respect to the use of ...

متن کامل

Long-life Xlpe Insulated Power Cable

Crosslinked polyethylene (XLPE) has become the globally preferred insulation for power cables, both for distribution and transmission system applications. This insulation system provides cost efficiency in operation and procurement, as well as lower environmental and maintenance requirements when compared to older impregnated paper systems. The purpose of this paper is to outline some of the de...