Shear Behavior of Single Cast-in Anchors in Plastic Hinge Zones
This paper presents two shear tests of -in. diameter cast-in anchors embedded in the plastic hinge zone of reinforced concrete columns. Design codes, such as ACI 318-14, require special reinforcement for concrete anchors in concrete that could be substantially damaged during an earthquake. The test anchors in this study were equipped with the anchor reinforcement recommended and verified in the...
متن کاملundrained triaxial shear behavior of grouted carbonate sands
the effects of cementation and the physical properties of grains on the shear behavior of grouted sands are investigated in this paper. the consolidated-undrained triaxial shear behavior of three grouted carbonate sands with different physical properties, including particle size distribution, particle shape and void ratio, was studied. two sands were obtained from the north shores of the persia...
متن کاملArthroscopic Labral Stabilization with Capsular Mattress Reinforcement Using Suture Anchors
Arthroscopic management of labral pathology has evolved in recent years with advancement in surgical techniques, aided by new instrumentation and implants designed to simplify the repair [1-5]. Results of arthroscopic stabilizations have been recently reported as equal or superior to open stabilizations with high rates of success, patient satisfaction and early return to activity [6-9]. The pur...
متن کاملLateral Load Tests on Small-Diameter Piles for Slope Remediation
Slope reinforcement and the use of structural pile elements can be an effective slope remediation alternative when conventional remediation practices (e.g., improved drainage) fail to consider the causal factors leading to slope instability (e.g., strength loss due to weathering). An experimental research program was aimed at developing a rapid, cost-effective, and simple remediation system tha...
متن کاملEffect of Mortar Type on the Seismic Response of Partially Grouted Reinforced Masonry Shear Walls
Since the establishment of ASTM standard C91, masonry cement mortars have become widely used for masonry construction in low to moderate seismic regions. However, the Masonry Standards Joint Committee Code prohibits the use of masonry cement mortars in lateral force resisting systems for structures that fall into Seismic Design Categories D, E, and F. The general objective of this study is to e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ACI Structural Journal
سال: 2019
ISSN: 0889-3241