Uncomplicated percutaneous IVC filter removal following implantation time of 6033 days
نویسندگان
چکیده
منابع مشابه
Endovascular management of IVC syndrome after IVC filter placement.
Approximately 60,000-100,000 Americans die from deep venous thrombosis or pulmonary embolism annually, while the overall estimate of individuals affected is 30,000-600,000. Inferior vena cava (IVC) filter placement has emerged as a break-through endovascular technique which has gained increasing acceptance and has probably saved thousands of lives by preventing fatal thromboembolic events. Howe...
متن کاملInferior vena cava filter removal after prolonged dwell time of 2310 days.
Inferior vena cava filters are commonly placed for a variety of indications, often when anticoagulation is contraindicated. Although technical success is high and complication rates low, there are complications that are important to be aware of. We present the case of a 29-year-old woman with a prolonged filter dwell time resulting in complications.
متن کاملTine after tine: a varied approach to the removal of a long-standing IVC filter
Inferior vena cava filters are important tools used to help prevent life-threatening pulmonary embolisms in hospitalized patients with contraindications to pharmacological prophylactic anticoagulation. This is a case report of a patient who had an inferior vena cava filter placed after a traumatic subdural hematoma. He made a complete recovery but was lost to follow-up until he presented 1825 d...
متن کاملSuccessful Percutaneous Retrieval of IVC Filter with Wide Retroperitoneal Penetration Presenting with Gastrointestinal Bleeding
Symptomatic penetration of the retroperitoneal structures by inferior vena cava (IVC) filter is a rare clinical entity. Vast majority of these patients require laparotomy and open retrieval of the filter. We report a case of a filter penetrating into the duodenum within two months of implantation resulting in gastrointestinal bleeding. The patient was successfully managed with percutaneous retr...
متن کاملThe Successful Removal of Two Retrievable Inferior Vena Cava (IVC) Filters after 67 Days in a Patient with a Double IVC
We herein present a case in which two retrievable inferior vena cava (IVC) filters, which were implanted to treat deep-vein thrombosis caused by the compression of a double IVC, were successfully removed on the 67th day after placement. The filters were individually placed in both the left and right IVCs. With a prevalence of only 0.2%, a double IVC is an extremely rare anatomical variation. Th...