Uncertainty of VNA S-parameter measurement due to non-ideal TMSO or LMSO calibration standards
نویسندگان
چکیده
منابع مشابه
Radon Measurement Standards and Calibration
This issue of the Journal of Research of the National Institute of Standards and Technology resulted from a one-half day seminar devoted to descriptions of the current status of the metrology of radon in international laboratories specializing in that area. The seminar, held June 5, 1989, at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Federal Republic of Germany was co-sponso...
متن کاملThe Voltage and Time Parameter Measurement Uncertainties of a Large Damped Capacitor Divider due to its Non-ideal Step Response
Limited frequency response of impulse voltage dividers contributes to the measurement errors of the peak voltage and time parameters. This paper investigates the convolution method for the determination of the errors of lightning impulse parameters due to non-ideal step responses. The step response of a damped capacitor divider with a voltage rating of 2.2 MV was measured and analytical lightni...
متن کاملUncertainty Quanti cation in Calibration of AFM Probes Due to Non-uniform Cantilevers
For more than two decades, the Atomic Force Microscope (AFM) has provided valuable insights in nanoscale phenomena, and it is now widely employed by scientists from various disciplines. AFMs use a cantilever beam with a sharp tip to scan the surface of a sample both to image it and to perform mechanical testing. Since the AFM measures the de ection of the probe beam, one must rst nd the spring ...
متن کاملCalibration and Standards in Flow Measurement
Calibration is defined as follows: ‘The set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards.’ It is important to recognize at the outset the definition of a ‘calibration’ and to note that the ‘comparison’ applies only to the condition...
متن کاملMeasurement Uncertainty Evaluation Associated with Calibration Functions
− Calibration procedures are widely implemented in metrology. This paper considers the evaluation of measurement uncertainty associated with the use of a calibration function. Three methods for uncertainty evaluation are described and the differences in the results returned are discussed. A simple calibration function is used to illustrate these differences.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Radio Science
سال: 2003
ISSN: 1684-9973
DOI: 10.5194/ars-1-1-2003