Results of uncemented porous-coated anatomic total hip replacement.
We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed gi...
متن کاملMid-Term Clinical Results of VerSys Hip System (Zimmer) Uncemented Total Hip Replacement Arthroplasty.
Recent reports suggest that uncemented total hip replacement arthroplasty (THR) results in favorable short- to mid-term clinical results. In the present study, we assessed the mid-term clinical results of VerSys Hip System uncemented THR at our hospital. MATERIALS AND METHODS We studied patients who received THR using VerSys Hip System and who could be followed-up more than 3 years. Clinical ...
متن کاملMetal on metal hip resurfacing versus uncemented custom total hip replacement - early results
INTRODUCTION There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA) of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR) has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been en...
متن کاملBilateral, uncemented total hip arthroplasty in osteopetrosis.
Bilateral, uncemented hip replacements were performed on a 45-year-old woman with autosomal dominant osteopetrosis. The hips showed degenerative changes and protrusio acetabuli. Difficulties were encountered especially during preparation of the femoral canal. At ten-year follow-up she has an excellent clinical and radiological result with no sign of osteolysis. Uncemented hip replacement, while...
متن کاملThe Ring uncemented plastic-on-metal total hip replacement. Five-year results.
The Ring plastic-on-metal total hip replacement was introduced with the intention of combining the advantages of the cemented low-friction arthroplasty with those of a cementless system. Fourteen hundred and eighty-eight of these procedures have been reviewed. The results of a two to seven-year follow-up, and of a group which has completed at least five years are presented. There was an excelle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Royal Society of Medicine
سال: 1981
ISSN: 0141-0768,1758-1095
DOI: 10.1177/014107688107401003