Robust nonlinear control of shunt active filters for harmonic current compensation

An advanced control strategy of shunt active filters (SAF) aiming to compensate for harmonic current in the electric supply grid is proposed. The SAF considered here is suitable for three-phase three-wire current harmonic compensation and is based on AC/DC three-phase boost converter topology. Robust control of the active-reactive current/power delivered by the SAF is designed exploiting the in...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Adaptive Nonlinear Control of Three-Phase Shunt Active Power Filters

The problem of controlling three-phase shunt active power filters (SAPF) is addressed in presence of nonlinear loads supplied with three-phase power grids. The SAPF-load system is shown to be modeled, in the ( , ) coordinate frame, by a third-order nonlinear state-space representation. The control objective is twofold: (i) compensating for the current harmonics and the reactive power absorbed b...

متن کامل

Noise compensation using interacting multiple kalman filters

This paper presents an approach to compensate the effects of noise with an Interacting Multiple Model algorithm using Unscented Kalman Filters (IMM-UKF) in log-spectral domain. The performance of this approach is studied experimentally on a continuous digits recognition task with additive noise conditions and compared with results previously obtained by the implementation of the Interacting Mul...

متن کامل

Analysis And Simulation Of Shunt Active Power Filter Under Unbalanced And Distorted Load Conditions

Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...