Unbalanced Variable Nonlinear Load Compensation Using Multiple Shunt Active Filters
نویسندگان
چکیده
منابع مشابه
Robust nonlinear control of shunt active filters for harmonic current compensation
An advanced control strategy of shunt active filters (SAF) aiming to compensate for harmonic current in the electric supply grid is proposed. The SAF considered here is suitable for three-phase three-wire current harmonic compensation and is based on AC/DC three-phase boost converter topology. Robust control of the active-reactive current/power delivered by the SAF is designed exploiting the in...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملAdaptive Nonlinear Control of Three-Phase Shunt Active Power Filters
The problem of controlling three-phase shunt active power filters (SAPF) is addressed in presence of nonlinear loads supplied with three-phase power grids. The SAPF-load system is shown to be modeled, in the ( , ) coordinate frame, by a third-order nonlinear state-space representation. The control objective is twofold: (i) compensating for the current harmonics and the reactive power absorbed b...
متن کاملNoise compensation using interacting multiple kalman filters
This paper presents an approach to compensate the effects of noise with an Interacting Multiple Model algorithm using Unscented Kalman Filters (IMM-UKF) in log-spectral domain. The performance of this approach is studied experimentally on a continuous digits recognition task with additive noise conditions and compared with results previously obtained by the implementation of the Interacting Mul...
متن کاملAnalysis And Simulation Of Shunt Active Power Filter Under Unbalanced And Distorted Load Conditions
Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)
سال: 2015
ISSN: 2088-8708,2088-8708
DOI: 10.11591/ijece.v5i5.pp896-904