Widefield heterodyne interferometry using a custom CMOS modulated light camera.
In this paper a method of taking widefield heterodyne interferograms using a prototype modulated light camera is described. This custom CMOS modulated light camera (MLC) uses analogue quadrature demodulation at each pixel to output the phase and amplitude of the modulated light as DC voltages. The heterodyne interference fringe patterns are generated using an acousto-optical frequency shifter (...
متن کاملPatel, Rikesh and Achamfuo-Yeboah, Samuel and Light, Roger and Clark, Matt (2012) Ultrastable heterodyne interferometer system using a CMOS modulated light
A novel ultrastable widefield interferometer is presented. This uses a modulated light camera (MLC) to capture and stabilise the interferogram in the widefield heterodyne interferometer. This system eliminates the contribution of piston phase to the interferogram without the need for common path optics and results in a highly stable widefield interferometer. The MLC uses quadrature demodulation...
متن کاملModulated CMOS camera for fluorescence lifetime microscopy.
Widefield frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) is a fast and accurate method to measure the fluorescence lifetime of entire images. However, the complexity and high costs involved in construction of such a system limit the extensive use of this technique. PCO AG recently released the first luminescence lifetime imaging camera based on a high frequency modulated CM...
متن کاملPatel, Rikesh and Achamfuo-Yeboah, Samuel and Light, Roger and Clark, Matt (2011) Widefield heterodyne interferometry using a custom CMOS modulated light
In this paper a method of taking widefield heterodyne interferograms using a prototype modulated light camera is described. This custom CMOS modulated light camera (MLC) uses analogue quadrature demodulation at each pixel to output the phase and amplitude of the modulated light as DC voltages. The heterodyne interference fringe patterns are generated using an acousto-optical frequency shifter (...
متن کاملA Proposed Simple Teleradiology System Using a Digital Camera
Background & Aims: Teleradiology as an efficient way for avoiding unnecessary transfer of patients to special medical centers requires the images with digital format. However, in some developing countries, including Iran, imaging is being done using non digital devices. In such cases, changing analog images into digital ones can solve the problem. The method which is nowadays used for digita...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2012
ISSN: 1094-4087
DOI: 10.1364/oe.20.017722