منابع مشابه
Ultrasound guided supraclavicular block.
Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.
متن کاملUltrasound-guided supraclavicular brachial plexus block.
UNLABELLED In this study, we evaluated state-of-the-art ultrasound technology for supraclavicular brachial plexus blocks in 40 outpatients. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. T...
متن کاملCases series: ultrasound-guided supraclavicular block in 105 patients
BACKGROUND Multiple needle attempts to gain a muscle twitch or a paresthesia for a classical supraclavicular brachial plexus block can increase the risks of nerve damage or pain. The aims of this study were to obtain reliable clinical data on ultrasound-guided supraclavicular blocks, demonstrate the higher success rate and fewer complications, and design an injection method for patients whose b...
متن کاملMinimum effective volume of mepivacaine for ultrasound-guided supraclavicular block
BACKGROUND The aim of this study was to estimate the minimum effective volume (MEV) of 1.5% mepivacaine for ultrasound-guided supraclavicular block by placing the needle near the lower trunk of brachial plexus and multiple injections. METHODS Thirty patients undergoing forearm and hand surgery received ultrasound-guided supraclavicular block with 1.5% mepivacaine. The initial volume of local ...
متن کاملAnatomic Variation of Subclavian Artery Visualized on Ultrasound-Guided Supraclavicular Brachial Plexus Block
Use of ultrasonography for performance of nerve and plexus blocks has made the process simpler and safer. However, at times, variant anatomy of the visualized structures can lead to failure of blocks or complications such as intravascular injections. This is especially true in case of novice operators. We report a case of a variant branch of subclavian artery, possibly the dorsal scapular arter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Ultrasonography
سال: 2013
ISSN: 1844-4172,2066-8643
DOI: 10.11152/mu.2013.2066.153.dh1mg2