Ultrasound Device Calibration
نویسندگان
چکیده
منابع مشابه
ICARE Radon Calibration Device
An aerodynamic calibration device called ICARE is briefly described. ICARE is currently being used at the Nuclear Research Center of Saclay in France for the certification of instruments employed in measurement of artificial radioactive particulate airborne contamination. ICARE is essentially a blower. Aerosols calibrated in size and labelled with 137Cs or 239Pu are injected in the mainstream o...
متن کاملCalibration Algorithm for Freehand Ultrasound
Ultrasound (US) image 3-D calibration for freehand probe is an extremely important technique in computerize 3-D ultrasonic (US image model reconstruction).Calibration is a procedure to calculate the spatial relationship between the US image and the tracker attached to the US probe. In this research, a different cross-string phantom and the corresponding algorithm are presented. The phantom with...
متن کاملFreehand Three-Dimensional Ultrasound Calibration
Freehand three-dimensional (3D) ultrasound is a technique for acquiring ultrasonic data of a 3D volume with application in radiotherapy and surgery planning. As the clinician sweeps the ultrasound probe over the anatomy, the trajectory of the probe is recorded using an attached position sensor. However, the position sensor tracks the position of the sensor, rather than the ultrasound B-scan. It...
متن کاملUltrasound-assisted wound debridement device
Debridement takes away nonvascularised tissue and cells that may obstruct wound contraction, the formation of granulation tissue and the migration of epithelial cells from the wound edge (Falanga, 2000) to create This article describes a new type of mechanical debridement that uses lowfrequency ultrasound technology, and presents case reports that highlight the use of the Sonoca® (Soring) ultra...
متن کاملDevice Simulator Calibration for Quartermicron CMOS Devices
We present the calibration of a device simulator for a 0.25 ftm CMOS technology using response surface methodology. For this process several measurements for different gate lengths (0.2-4.0 /jm) were made. Care was taken to eliminate the statistical variations typical to sub-micron devices by measuring several chips on the the same wafer and taking an average sample. The simulations carried out...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Therapy
سال: 2002
ISSN: 0031-9023,1538-6724
DOI: 10.1093/ptj/82.11.1144