Ultrasound detection using polymer microring optical resonator
نویسندگان
چکیده
منابع مشابه
Free-standing all-polymer microring resonator optical filter - Electronics Letters
Free-standing all-polymer microring resonator optical filters as prototypical elements in flexible integrated lightwave circuits are demonstrated. The fabrication and measurement methods are discussed. The measured spectrum shows good agreement with theoretical expectations. The crucial ‘critical’ coupling condition is achieved, resulting in a measurement limited 27 dB extinction of the filter ...
متن کاملLow-noise wideband ultrasound detection using polymer microring resonators.
Polymer microring resonators for low-noise, wideband ultrasound detection are presented. Using a nanoimprinting technique, we fabricated polymer microring resonators with a quality factor of 6000 resulting in high sensitivity to ultrasound. A noise-equivalent pressure of 0.23 kPa over 1-75 MHz and a detection bandwidth of over 90 MHz at -3 dB were measured. These results demonstrate the potenti...
متن کاملHCMT models of optical microring-resonator circuits
1 Ringresonator modelling Optical microresonator circuits [1, 2, 3] are considered, consisting of a number of not necessarily identical circular cavities and straight waveguides, with evanescent wave interaction between these elements. A simple configuration with a single cavity and two straight bus waveguides serves as an example to explain the frequency-domain Hybrid analytical/numerical Coup...
متن کاملOptical microring resonator based corrosion sensing
Nanotechnology Laboratory, School of E Birmingham B15 2TT, UK. E-mail: h.butt@b Integrated Lightwave Research Group, De Engineering, University of Malaya, Kuala Lu Harvard Medical School and Wellman C General Hospital, 65 Landsdowne Street, Ca Harvard-MIT Division of Health Sciences an Technology, Cambridge, MA, 02139, USA † Electronic supplementary informa 10.1039/c6ra11538a Cite this: RSC Adv...
متن کاملBiosensing Using Microring Resonator Interferograms
Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed th...