Ultrasound biomicroscopy in deep sclerectomy
نویسندگان
چکیده
منابع مشابه
[Ultrasound biomicroscopy in deep sclerectomy: case report].
Case report of a woman with the diagnosis of primary open-angle glaucoma who was submitted to a successful surgical procedure of deep sclerectomy in the right eye. In the postoperative period, at month 3, the surgical procedure was evaluated with ultrasound biomicroscopy (UBM) utilizing two distinct equipments (UBM 840-Zeiss; UBM-VUMAX-Sonomed), with 50-MHz transducers. The diagnostic method of...
متن کامل[Ultrasound biomicroscopy in deep sclerectomy with a new acrylic implant].
OBJECTIVE To describe the ultrasound biomicroscopic (UBM) characteristics seen in patients who have undergone deep phaco-sclerectomy with a new acrylic implant (Esnoper). SUBJECTS, MATERIAL AND METHODS UBM exploration was performed 12 months after deep phaco-sclerectomy in three patients with chronic open angle glaucoma. RESULTS One year after surgery, all three patients had intraocular pre...
متن کاملUltrasound biomicroscopy of eyes undergoing deep sclerectomy with collagen implant.
AIMS To assess the intraocular pressure (IOP) lowering mechanism of deep sclerectomy with collagen implant (DSCI), a non-penetrating glaucoma surgery. METHODS Nine eyes of nine patients with medically uncontrolled open angle glaucoma underwent DSCI. Ultrasound biomicroscopy (UBM) of the sclerectomy site was performed 1 month after surgery. The following factors were assessed: length and heigh...
متن کاملAn ultrasound biomicroscopy study after deep sclerectomy with supraciliary implant.
OBJECTIVE To evaluate patients 24 months after deep sclerectomy (DE) with supraciliary implant, and identify any predictive success factors by examination with ultrasound biomicroscopy (UBM) MATERIAL AND METHODS: This study included 26 eyes of 23 patients evaluated by UBM 24 months after a deep sclerectomy with a supraciliary hema implant. RESULTS There was a significant reduction in intraocu...
متن کاملUltrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant.
PURPOSE To identify the clinical and anatomic characteristics of filtering blebs after glaucoma surgery with a new biodegradable collagen implant, Ologen, using ultrasound biomicroscopy (UBM) and Visante anterior segment optical coherence tomography (OCT). METHODS The authors conducted a prospective interventional case series in 15 eyes with openangleglaucoma. The authors performed limbal-bas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2005
ISSN: 0950-222X,1476-5454
DOI: 10.1038/sj.eye.6701558