Ultrasonographic findings of posterior interosseous nerve syndrome
نویسندگان
چکیده
منابع مشابه
Ultrasonographic findings of posterior interosseous nerve syndrome
PURPOSE The purpose of this study was to evaluate the ultrasonographic findings associated with posterior interosseous nerve (PIN) syndrome. METHODS Approval from the Institutional Review Board was obtained. A retrospective review of 908 patients' sonographic images of the upper extremity from January 2001 to October 2010 revealed 10 patients suspicious for a PIN abnormality (7 male and 3 fem...
متن کاملUltrasonographic findings in isolated neuritis of the posterior interosseous nerve: comparison with normal findings.
solated palsy of the posterior interosseous nerve (PIN) can occur without nerve compression and is often referred to as isolated neuritis or neuralgic amyotrophy because of its characteristic elbow pain at the onset, lasting days to weeks with subsequent weakness. The diagnosis is based on the clinical course because, to our knowledge, there have been no objective tests, in particular imaging f...
متن کاملCase Report: POSTERIOR INTEROSSEOUS NERVE COMPRESSION SYNDROME
Radial nerve compression or injury can occur at any point along the course of the nerve within the upper extremity. Entrapment of the radial nerve or its branches is most common within the proximal forearm and at the elbow. Variations in anatomic structures at this level are an important cause of radial nerve entrapment syndromes. Compression of the radial nerve and its branches at the elbow ca...
متن کاملPosterior Interosseous Nerve Syndrome from Thermal Injury
Background. Due to anatomical proximity to bone, the radial nerve is the most frequently injured major nerve of the upper extremity, frequently secondary to fractures (Li et al. (2013)). We describe an incidence when a branch of the radial nerve is injured as a result of a thermal injury. Observation. Radial nerve injury can occur anywhere along the anatomical course with varied etiologies, but...
متن کاملPosterior Interosseous Nerve Compression
Figure 1. T2 turbo spin-echo weighted magnetic resonance imaging demonstrating a space-occupying lesion in the radial tunnel. L indicates lesion; R, proximal radius.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasonography
سال: 2017
ISSN: 2288-5919,2288-5943
DOI: 10.14366/usg.17007