Ultrasonic partial discharge monitoring method on instrument transformers
نویسندگان
چکیده
منابع مشابه
Partial Discharge Monitoring of Power Transformers by UHF Sensors
The reliability of electrical energy networks depends on both, the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these...
متن کاملAn Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers
Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new ...
متن کاملPartial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development...
متن کاملUhf and Acoustic Partial Discharge Localisation in Power Transformers
The reliability of electrical energy networks depends on the quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and can cause high outage and penalty costs. Beside the strength and type of a PD, the geometric PD position is of major interest concerning risk evaluation of the flaw. Conventional PD m...
متن کاملRF transformers for ultrasonic
Performance of electrical matching of an ultrasonic transducer to the excitation generator is analyzed. The analysis is based on a transducer measured impedance. Real power supplied to the ultrasonic transducer is one of evaluation criteria. The obtainable bandwidth as well as it’s product with a real power supplied are assigned as the alternative performance evaluation criteria. Effective band...