Ultrasensitive Seawater pH Measurement by Capacitive Readout of Potentiometric Sensors
نویسندگان
چکیده
منابع مشابه
Aspheric Surface Measurement Using Capacitive Sensors
This paper proposes a new method for the measurement of spherical coordinates by using capacitive sensors as a non-contact probe solution of measurement of aspheric surfaces. The measurement of the average effect of the capacitive probe and the influence of capacitive probe tilting were studied with respect to an eccentric spherical surface. Based on the tested characteristic curve of the avera...
متن کاملPotentiometric miniaturized pH sensors based on polypyrrole films
Submitted by Olivier Segut on Fri, 11/07/2014 16:35 Titre Potentiometric miniaturized pH sensors based on polypyrrole films Type de publication Article de revue Auteur Lakard, Boris [1], Segut, Olivier [2], Lakard, Sophie [3], Herlem, Guillaume [4], Gharbi, Tijani [5] Editeur Elsevier Type Article scientifique dans une revue à comité de lecture Année 2007 Langue Anglais Date Jan-03-2007 Numéro ...
متن کاملCmos Readout Interfaces for Mems Capacitive Microphones
This dissertation demonstrates the feasibility of three novel low-power and low-noise schemes for the readout interfaces of MEMS Capacitive Microphones (MCM) by presenting their detailed design descriptions and measurement results as application-specific ICs (ASIC) in CMOS technology developed to exploit their application scope in consumer electronics and hearing aids. MCMs are a new generation...
متن کاملSpoofing Capacitive Fingerprint Sensors
This white paper discusses methods and findings from one of Novetta’s many approaches to vulnerability assessment: the fabrication of non-gelatinous artifacts for capacitive fingerprint sensors. We present methods of evaluating artifact performance relative to that of live presentations and gummy fingerprint artifacts. Two sets of artifacts are comprised of latex face paint or acrylic fabric pa...
متن کاملFully-Differential Capacitive Sensors
Although sensors used in the majority of high-performance seismometers are capacitive, the performance of present commercial instruments is less than what it could be--due to the choice of less-than-optimal electrode configurations. The detector in commercial instruments has only one-half the symmetry of the patented symmetric differential capacitive (SDC) transducer, also known as 'fully diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ACS Sensors
سال: 2020
ISSN: 2379-3694,2379-3694
DOI: 10.1021/acssensors.0c00031