Ultra-low-dose CT combined with noise reduction techniques for quantification of emphysema in COPD patients: An intra-individual comparison study with standard-dose CT

نویسندگان

چکیده

Abstract Purpose Phantom studies in CT emphysema quantification show that iterative reconstruction and deep learning-based noise reduction (DLNR) allow lower radiation dose. We compared on ultra-low-dose (ULDCT) with without reduction, to standard-dose (SDCT) chronic obstructive pulmonary disease (COPD). Method Forty-nine COPD patients underwent ULDCT (third generation dual-source CT; 70ref-mAs, Sn-filter 100kVp; median CTDIvol 0.38 mGy) SDCT (64-multidetector 40mAs, 120kVp; 3.04 mGy). Scans were reconstructed filtered backprojection (FBP) soft kernel. For ULDCT, we also applied advanced modelled (ADMIRE), levels 1/3/5, DLNR, 1/3/5/9. Emphysema was quantified as Low Attenuation Value percentage (LAV%, ≤-950HU). measures reference standard. Results the dose 84 % than for SDCT. Median extent of 18.6 ULD-FBP 15.4 (inter-quartile range: 11.8–28.4 9.2 %–28.7 %, p = 0.002). Compared SDCT, range limits agreement measure variability 14.4 ULD-FBP, 11.0–13.1 ULD-ADMIRE 10.1–13.9 ULD-DLNR levels. Optimal settings ADMIRE 3 DLNR 3, reducing by 24 27 at slight underestimation (−1.5 −2.9 respectively). Conclusions Ultra-low-dose allows %. State-of-the-art methods resulted Noise (especially 3) reduced up FBP.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging

OBJECTIVES To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. MATERIALS AND METHODS Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different prot...

متن کامل

Stacked competitive networks for noise reduction in low-dose CT

Since absorption of X-ray radiation has the possibility of inducing cancerous, genetic and other diseases to patients, researches usually attempt to reduce the radiation dose. However, reduction of the radiation dose associated with CT scans will unavoidably increase the severity of noise and artifacts, which can seriously affect diagnostic confidence. Due to the outstanding performance of deep...

متن کامل

Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma.

BACKGROUND AND PURPOSE The purpose of this work was to evaluate the possible use of low-dose multidetector CT (MDCT) in cervical clearance of patients with blunt trauma. MATERIALS AND METHODS A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose (n = 51) and low-dose MDCT with tube current modulation at high (n = 70) and low (n = 70) tube voltage (kilovolts)...

متن کامل

Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

OBJECTIVES Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. METHODS Patients (n=475) younger...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Radiology

سال: 2021

ISSN: ['0720-048X', '1872-7727']

DOI: https://doi.org/10.1016/j.ejrad.2021.109646