Ultra-high Strength Concrete on Eccentrically Loaded Slender Circular Concrete-filled Dual Steel Columns
نویسندگان
چکیده
منابع مشابه
Numerical Simulation of Ultra- Strength Concrete-filled Steel Columns
Article history: Received: 11. 09. 2013. Received in revised form: 01. 10. 2013. Accepted: 15. 10. 2013. Researches into the constitutive relation of the super high strength and high performance concrete and the stress strain relationship of the ultrastrength concrete-filled steel columns are rare. Therefore, this paper based on continuous mechanics presents the relationship of mathematical des...
متن کاملAmbient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملFire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملEffect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes
In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...
متن کاملFlexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Structures
سال: 2017
ISSN: 2352-0124
DOI: 10.1016/j.istruc.2017.07.005