UJI INTERKOMPARASI METODE AAN DAN XRF UNTUK ANALISIS SAMPEL SEDIMEN IAEA INTER COMPARISON TEST OF NAA AND XRF METHOD FOR IAEA SEDIMENT SAMPLE ANALYSIS
نویسندگان
چکیده
منابع مشابه
Frequency of thalassemia carrier and Hb variant and the quality of stored donor blood
Metode: Penelitian ini menggunakan disain potong lintang dengan sampel berasal dari 138 donor darah. Dilakukan skrining talasemia dan Hb varian pada keseluruhan sampel, yang meliputi pemeriksaan hitung sel darah lengkap, analisis Hb metode HPLC dan analisis DNA untuk deteksi pembawa sifat talasemia α. Uji kualitas darah simpan dilakukan melalui penghitungan persen hemolisis sel darah merah pada...
متن کاملDissolution test of various low-dose acetylsalicylic acid preparations marketed in Indonesia
Metode Studi disolusi dilakukan mengikuti Farmakope Amerika (USP)/Eropa, metode A, menggunakan alat 1 USP (keranjang) 100 rpm, dengan 2 media: 0,1 N HCl, 120 menit untuk stadium asam, dan buffer fosfat pH 6,8, 90 menit untuk stadium dapar. Sampel diambil pada 120 menit untuk stadium asam, dan setiap 10 menit sampai dengan 90 menit untuk stadium dapar. Asam asetilsalisilat diukur kadarnya dengan...
متن کاملExperimental Parameters for XRF Analysis of Soils
Harmful elements (Pb, Se, Cd, etc.) in the soil samples were measured by X-ray fluorescence (XRF) method. We investigated the influence of the thickness of soil layer, the grain size of soils, and the water content in soils on XRF intensity. Since high-energy XRF such as Cd K was detected in deep inside of soils, a thickness of 10 mm was recommended. The soil sample with a small grain size gave...
متن کاملXRF-FP is a full-featured quantitative analysis package for XRF
AMPTEK INC. 14 DeAngelo Drive, Bedford, MA 01730-2204 U.S.A. APPLICATIONS • X-Ray Fluorescence • Thin-film Analysis • RoHS/WEEE Analysis • Teaching and Research • Art and Archaeology • Process Control • X-ray Tube Characterization FEATURES • Fundamental parameters (FP) • Analysis with or without standards • General bulk and thin-film analysis • Analyze up to 40 elements • Supports all Amptek de...
متن کاملPIXE and XRF analysis of honey samples
The systematic determination of trace-element concentrations in honey samples was done by the PIXE method using a 2 MeV proton beam and by the total reflection XRF method. The different kinds of honey samples were collected in the period of spring–summer in three places of Poland: in the centre of Warsaw (a highly polluted region) and about 100 km east of Warsaw and 70 km southwest of Warsaw (a...